EMU Professional II 3/100 LoRa MID energy meter, external antenna

SKU:3AJT
Cod. produttore:P20A000LE
Marca:EMU Electronic
Categorie:
Disponibilità CH:
pronto per la spedizione4
Da magazzino esterno:
Tempo di consegnain ca. 20 giorni
Il termine vale a partire da 10 pezzi. Per quantità inferiori chiedeteci. (?)

CHF361.50 IVA escl.

più spese di spedizione

Three-phase energy meter with MID B + D approval that reports its readings over LoRaWAN — billing-grade, without a data cable in the distribution board. Direct connection up to 100 A, five modules wide, load profile over three years at 15-minute intervals. This version adds an SMA socket to the internal antenna so the signal also gets out of a closed metal cabinet. The external antenna is not included; the socket is SMA female, so an antenna with an SMA male plug is required.

! Per utilizzare questo dispositivo serve una rete LoRaWAN. Potete crearla voi stessi con un gateway LoRaWAN, usare la rete LORIOT o TTN, oppure la rete Swisscom LoRaWAN che copre tutta la Svizzera. Tutte queste reti sono acquistabili da noi.
 Aggiungi al confronto

The EMU Professional II 3/100 LoRa is a three-phase, MID-approved energy meter that reports its readings over LoRaWAN. That is the whole point: you do not get a monitoring meter but a billing-grade meter whose data leaves the distribution board without a data cable. Tenants, cost centres and charging points can therefore be billed where nobody ever pulled a cable. This version adds an SMA socket for an external antenna to the internal one — the difference that decides, inside a sheet-metal cabinet, between a radio link and radio silence. It connects directly, without current transformers; in the board it occupies five modules. Built by EMU Electronic in Baar, Switzerland.

  • 100 Adirect connection, no transformers
  • MID B + Dbilling-grade
  • Class B1 % active energy
  • over 3 yearsload profile at 15-minute intervals
  • SMAsocket for an external antenna

What sets the Professional II LoRa apart

  • Billing, not just watching: MID approval B + D is the difference between a meter that shows you something and one whose readings you are allowed to invoice against. Anyone billing tenants for electricity or charging internal cost centres needs exactly that — a measuring device without approval will not do, however accurately it measures.
  • The external antenna is the reason this version exists: a sheet-metal distribution board is a Faraday cage. The internal antenna is enough in a plastic board or with the door open, but often not in a closed steel cabinet. Through the SMA socket you put the antenna where it has a view — outside the cabinet or in the room. That is what separates it from the sister version without the socket.
  • The meter is its own archive: the load profile memory holds the main readings at 15-minute intervals for over three years, and does so to PTB-A 50.7. If the radio link drops for a week, nothing is missing afterwards; the data is in the device. For billing that depends on unbroken series, that matters more than any data rate.
  • Class C: reachable at any time: the meter listens continuously instead of only briefly after transmitting. Configuration changes and queries therefore take effect immediately, not at the next uplink. Where the network does not carry class C, it continues as a class A device.
  • You decide what gets sent: the interval and content of the uplinks are freely configurable. A meter that only delivers the index for the monthly invoice transmits differently from one feeding a load profile — the same device does both.
  • Two directions kept apart: import and export are counted separately. With a photovoltaic system that is the precondition for separating third-party quantities — without separate registers, self-consumption cannot be cleanly told apart from feed-in.
  • The clock sets itself: time synchronisation runs over the LoRa network. On a meter whose timestamped values feed into billing, a drifting clock is not a cosmetic flaw but a data problem.
  • Decoders are ready: decoders and encoders are lodged with The Things Network and freely available for other systems. Integration therefore starts with finished readings, not with byte analysis.
  • Two routes alongside: a volt-free S0 pulse output and the optical D0 interface to EN 62056-21 are there as well. The S0 output is the fallback if the radio link cannot be established — and the reading interface remains available independently.
  • Readable without tools: the backlit graphic LCD shows readings, configuration and the state of the LoRa link directly on the device. Anyone standing in the basement wanting to know whether the meter is on the network does not need the dashboard.
  • Data survives the power: the register values sit in EEPROM without voltage, for at least ten years. The internal clock bridges up to 18 days without supply.
  • Swiss manufacture: developed and built by EMU Electronic in Baar. Housing of halogen-free, recyclable polycarbonate.

Where it is used

  • Tenant electricity and self-consumption communities: the main case in Switzerland. Every unit gets its meter, the readings come together by radio — without pulling a data cable to the stairwell for each measuring point.
  • Cost-centre billing in business: halls, departments or individual machines recorded separately and charged internally. MID approval makes the figures hard to argue with.
  • Separating third-party quantities in self-generation: anyone generating electricity and passing it on must prove which quantity went where. Bidirectional metering provides the basis.
  • Charging infrastructure: bill charging points individually, including in underground car parks where a network connection would be costly.
  • Energy management to ISO 50001: consumption transparency as the basis for measures and their evidence.
  • Sub-metering in existing buildings: retrofitting without a cable route — the most common reason radio wins here rather than Modbus.
  • Rollouts across properties: one meter type across many buildings, read centrally. Because installation and connection need no wiring, it scales from one building to an entire portfolio.
The antenna is not included — and the socket is SMA female. Despite the ext. Ant. in the name, no external antenna comes with the meter; it brings only the socket. You therefore additionally need an antenna with an SMA male plug. This detail appears in no manufacturer document — we checked the socket ourselves on a device from our own stock. This is the point at which the wrong antenna otherwise gets ordered: RP-SMA looks the same and does not fit. Which antenna makes sense is set out below under Matching accessories.
Three points before ordering. First, the connection: this device measures directly up to 100 A. Above that, the transformer version EMU Professional II 3/5 belongs, which we gladly source. Second — and this is the point the manufacturer writes into its own device-selection advice: a directly connected meter can only be replaced with the installation switched off. If replacement because of expired calibration validity comes due in your application one day, and shutting down is expensive or impossible there, the transformer version is the cheaper choice despite the higher initial cost. That is a decision for the next fifteen years, not for next week’s installation. Third: installation belongs in the hands of a qualified electrician — there is 400 V here. And like every LoRaWAN device, the meter needs a network: a public one such as Swisscom or The Things Network, or a gateway of your own. If a network cable reaches the board anyway, the TCP/IP version is the more direct and faster route.

That settles the selection. What follows is the depth for planning and integration.

What MID approval means in practice

MID stands for the European Measuring Instruments Directive; B + D denotes the conformity procedure: type examination by a notified body plus supervised manufacture. For you this means the readings of this meter are fit to be the basis of an invoice between two parties — without you having to prove measuring accuracy in a dispute. A device without approval can achieve the same accuracy and still be unusable for billing. The difference lies not in the technology but in the legal framework.

Accuracy class B to EN 50470-3 means a permissible deviation of one per cent on active energy. For reactive energy, class 2 to EN 62053 applies, so two per cent — reactive energy is not part of the MID in approval terms and is measured by the meter but not certified in the same way. The meter additionally carries PTB approvals 20.1 and 50.7; the latter covers the calibration-law-compliant load profile memory.

On calibration validity: in Switzerland, electricity measuring instruments are subject to mandatory calibration, and the period of validity is limited. Plan meter replacement as a recurring item, not a one-off installation — this is exactly what the choice between direct and transformer connection in the box above hangs on. This assessment comes from practical application and is to be understood as a selection aid, not as legal advice; the binding information comes from the Federal Institute of Metrology.

Radio inside the cabinet — what matters

The most common cause of a poor link is not the distance to the gateway but the cabinet itself. A steel sheet board attenuates the 868 MHz signal so strongly that a meter three metres from the gateway fares worse than one with a clear view over two hundred metres. That is exactly what this version is for: the antenna moves outside through the SMA socket.

What has proven itself is an antenna led out of the cabinet and mounted as high and as clear as possible — not against the inner wall and not right next to contactors or frequency converters, whose interference degrades reception further. With several meters in the same distribution, a radio test at the least favourable point is worthwhile before twenty devices are installed. Transmit power is 14 dBm, that is the regulatory maximum of the band — there is nothing to gain there; the improvement comes solely from antenna position and gateway location.

One point of orientation: the meter is mains powered. Transmit frequency therefore costs no battery here, only airtime. The legal limit on transmission duration still applies — anyone sending a full measurement packet every five minutes should keep an eye on it, especially where many devices transmit from the same place.

Operating effort

No battery, no maintenance cycle in the usual sense — the effort lies in self-consumption and in replacing the meter when calibration validity expires.

Self-consumption, voltage path0.8 VA or 0.8 W per phase
Continuous draw, three-phasearound 2.4 W, so roughly 21 kWh per year
Power supplyfrom the measured mains, no separate auxiliary supply
Recurringmeter replacement when calibration validity expires

For project planning this means: running operation costs nothing beyond self-consumption, and that is unavoidable on a device of this class. The predictable item is the replacement — and whether it requires a shutdown is decided by the choice between direct and transformer connection.

Integration

The meter joins the network by OTAA or ABP; OTAA is set at the factory. The DevEUI begins with 102CEF, the AppEUI is 10 2C EF 00 00 00 00 00, and both, along with the AppKey, can be read directly on the display — commissioning needs no tool and no software, only the two buttons on the device.

For the payload, decoders and encoders are lodged with The Things Network and freely available from the manufacturer. Which readings appear in the uplink is up to you: active energy in both directions, active power, current, voltage and power factor per phase, plus the mains frequency. The meter writes the same quantities into its internal load profile memory, so a radio gap can be filled in later.

Because the device works as class C, downlinks are possible at any time — interval and content can therefore be changed in service, without sending anyone to the basement. Operation is possible both on public networks such as Swisscom, LORIOT and The Things Network and on a network you run yourself.

Versions

We stock the version with direct connection and an external antenna socket. We gladly source the remaining versions of the Professional II family on request.

VersionConnectionPart numberAvailability
Professional II 3/100 LoRa external antennadirect up to 100 AP20A000LEThis is the version you order here
Professional II 3/100 LoRadirect up to 100 AP20A000LOon request — internal antenna only
Professional II 3/5 LoRa external antennatransformer /5 and /1 AP21A000LEon request
Professional II 3/5 LoRatransformer /5 and /1 AP21A000LOon request
Professional II 3/100 TCP/IPdirect up to 100 AP20A000Ton request — when the network reaches the board
Professional II 3/100 Modbus RTUdirect up to 100 AP20A000MOon request
Professional II 3/100 M-Busdirect up to 100 AP20A000Mon request
Professional II 3/100 without interfacedirect up to 100 AP20A0000on request

Technical data

The general product data — protection rating, dimensions, weight, housing, temperature range, manufacturer part number and origin — is in the detail table further down this page.

Measurement
Active energyclass B (1 %) to EN 50470-3
Reactive energyclass 2 (2 %) to EN 62053
Operating voltage3 × 230/400 V AC, L-L 400 V ±20 %, L-N 230 V ±20 %
Maximum current100 A, direct connection
Starting current20 mA at power factor 1
Mains frequency50 Hz nominal (60 Hz on request), limit frequencies 40 … 65 Hz
Self-consumptionvoltage path 0.8 VA / 0.8 W per phase
Measuring directionbidirectional, import and export separate
Tariffs2 or 4 tariffs, configurable at the meter, switching via 230 V AC
Memory and clock
Load profile memoryover 3 years at 15-minute intervals, to PTB-A 50.7
Logged valuesactive energy import and export, active power, current, voltage and power factor per phase, frequency
Data retentionin EEPROM without voltage, at least 10 years
Clockbuffered up to 18 days, synchronised over the LoRa network
LoRaWAN
Frequency bandEU 863 … 870 MHz
Device classclass C, operation as class A possible
Transmit power14 dBm
Antennainternal built in, plus an SMA socket (SMA female) for an external antenna with an SMA male plug; external antenna not included
Join procedureOTAA and ABP, OTAA from the factory
Uplinkinterval and content freely configurable
Decoderlodged with The Things Network, freely available
Further interfaces
S0 pulse outputEN 62053-31, volt-free, 1 / 10 / 100 / 1000 / 10,000 pulses per kWh, pulse length 2 / 10 / 30 / 40 / 120 ms, adjustable at the meter
Optical interfaceD0 to EN 62056-21
Display and connection
Displaybacklit graphic LCD, 38 × 28 mm, dynamic 8-digit with up to three decimal places
Conductor cross-section1.5 … 35 mm²
Tightening torque2 Nm, 3 Nm maximum
Mounting35 mm DIN rail or front-panel frame, position independent, 5 modules wide
Approvals and environment
ApprovalsCE, MID B + D, PTB-A 20.1, PTB-A 50.7; suitable for energy management to ISO 50001
Protection classII
Environment classesmechanical M2, electromagnetic E2
Humidityannual mean 75 %, briefly 90 %, non-condensing

Installation and commissioning

The meter clips onto the 35 mm DIN rail and occupies five modules, that is 90 mm. It is position independent, so it can also be fitted in a rotated distribution. For front-panel mounting there is a frame. The terminals take cross-sections from 1.5 to 35 mm²; the tightening torque is 2 Nm and must not exceed 3 Nm — on meters of this size, over-tightened terminals are a more frequent source of faults than loose ones.

After switching on, the display shows the state of the LoRa link. That is the moment at which it is decided whether the antenna position works — and the only convenient time to change it. Check reception before the board is closed and the cover fitted, not afterwards from the office.

Installation is reserved for a qualified electrician. For the transformer version the following also applies: current transformers must never be operated open-circuit, as dangerously high voltages can arise.

Scope of delivery

  • EMU Professional II 3/100 LoRa energy meter with internal antenna and SMA socket, part number P20A000LE
  • No external antenna. The socket is there, the antenna is ordered separately — see below.

Matching accessories

Help with sizing

The datasheet and manual are under the Documents tab at the top of this page. Unsure whether the direct connection is enough or the transformer version is the wiser choice, or how many gateways cover a property? Tell us how many measuring points and buildings are involved — the question of the right connection is gladly settled in conversation. And if it turns into a project — radio planning, pre-configuration in quantity or commissioning — we will gladly put together a quote.

+ Mostra altro

Dokumente

Recensioni

Ancora non ci sono recensioni.

Recensisci per primo “EMU Professional II 3/100 LoRa MID energy meter, external antenna”

Details

Generale
Marca
EMU Electronic
Codice produttore
P20A000LE
Colore
grigio chiaro
Interfaccia
D0 optisch
,
S0
Connettività
Connettività
LoRaWAN
Long Range Wide Area Network, ein drahtloses Protokoll für Low-Power-Geräte in weiträumigen Netzwerken, ideal für das IoT.
Classe dispositivo
C
Klasse C-Geräte haben fast ständige Empfangsfenster, außer wenn sie selbst senden. Diese Geräte verbrauchen mehr Energie, ermöglichen jedoch eine nahezu Echtzeitkommunikation. Ein IoT-gesteuertes Straßenbeleuchtungssystem, das auf sofortige Befehle zur Helligkeitsanpassung reagieren muss, könnte ein Klasse C-Gerät sein.
Antenna esterna
1x SMA Female LoRaWAN
Frequenze
EU868
LoRaWAN-Frequenzband für Europa (868 MHz). Verwendet in Ländern wie Deutschland, Frankreich, Großbritannien und den meisten anderen europäischen Ländern.
Alimentazione
Alimentazione
3x230/400 VAC
Meccanica/design
Codice IP / protezione
IP51
Intervallo di temperatura
-25 °C bis +70 °C
Collegamenti
SMA
,
SMA-Female
Informazioni commerciali
Paese d’origine
Svizzera
Altre caratteristiche
Sensori
corrente
Tipo di montaggio
DIN-Schiene
Luogo d’impiego
interno
Server di rete
ChirpStack
,
Loriot
,
Swisscom LPN
,
TTN