Dragino D22-LS LoRaWAN temperature sensor with two stainless steel probes IP66 (868 MHz) — solar

SKU:3JT4
Cod. produttore:D22-LS
Marca:Dragino
Categorie:
Sensoren:
Disponibilità CH:
non in magazzino0
Da magazzino esterno:
Tempo di consegnain ca. 20 giorni
Il termine vale a partire da 10 pezzi. Per quantità inferiori chiedeteci. (?)

CHF74.79 IVA escl.

più spese di spedizione

LoRaWAN temperature sensor with two remote stainless steel probes on 1.5 m of cable each: two DS18B20s from −55 to +125 °C, both values in the same message — the precondition for a clean temperature difference. IP66, recording when the network drops, 8500 mAh cell for up to five years.

! Per utilizzare questo dispositivo serve una rete LoRaWAN. Potete crearla voi stessi con un gateway LoRaWAN, usare la rete LORIOT o TTN, oppure la rete Swisscom LoRaWAN che copre tutta la Svizzera. Tutte queste reti sono acquistabili da noi.
 Aggiungi al confronto

The Dragino D22-LS measures in two places at once: two DS18B20 probes in stainless steel, each on 1.5 m of cable, on one device with one battery and one radio link. That is more than half the saving against two separate devices — on a flow and return, top and bottom of a cylinder, inside and outside the same wall, the difference is the real measured quantity, and it is only clean if both values come from the same message. This is the solar-powered version: a panel charges a rechargeable 3000 mAh Li-ion cell, and the battery change disappears as long as enough light arrives.

  • 2 channelstwo DS18B20 probes
  • −55 … 125 °Crange per probe
  • ±0.5 °Ctypical, max. ±2.0 °C
  • IP66enclosure, probes IP65
  • 3000 mAhLi-ion, solar charged

What defines the D22-LS

  • Both values from the same message: the two channels are sampled together and sent together. Anyone evaluating a temperature difference therefore gets it with no time offset — with two separate devices on their own reporting intervals, that is exactly the error nobody sees in the chart.
  • Two measuring points, one battery, one device: one device profile instead of two, one maintenance visit instead of two, one place in the network server’s inventory instead of two. Across a fleet that is the item that adds up over the years.
  • The probes can be told apart: Dragino marks them with a red and a white ring and carries them as separate channels in the payload. At installation it is therefore clear which value belongs to which measuring point — not a given with two identical-looking sensors.
  • A measuring range that covers most applications: −55 to +125 °C is not a marketing figure but the DS18B20’s range. The same device therefore measures in a deep-freeze store and on a heating flow.
  • Stainless steel, not plastic: both sensing elements sit in stainless sleeves rated IP65. They slide into thermowells, strap to pipes or push into bulk material — and they survive the cleaning that open sensors fail.
  • An alarm flag per channel: thresholds can be set for both probes together or for each individually; the message carries the alarm flag with it. The minimum time between two alarm messages is also set by downlink, so a sensor sitting on a limit does not flood the network.
  • Recording when the network drops: if coverage fails, the device writes timestamped readings to its own memory and sends them on once the network is back.
  • Device status on its own port: model, firmware version, frequency band and battery arrive on FPort 5, separate from the readings on FPort 2. For a fleet that means the inventory can be queried without searching the measurement database.
  • No battery change planned in: the solar panel charges a rechargeable 3000 mAh Li-ion cell. With sufficient light the replacement cycle disappears — at hard-to-reach measuring points the larger item over the service life. The cell is a buffer, not the main store: it carries the device overnight and through spells of bad weather.
  • Configuration over the air: reporting interval and thresholds are set by downlink. The device can also be configured on site over Bluetooth 5.1 and its firmware updated wirelessly.
  • Not tied to a platform: LoRaWAN 1.0.3, Class A, OTAA. Runs on TTN, ChirpStack and the Swisscom LPN with the same device profile and the same decoder.
  • One series, four probe fit-outs: one probe on the D20, a buriable one on the D20S, three on the D23. Payload layout, decoder and integration are the same for all of them — the channel a model does not fit reads a fixed value.

Where the D22-LS is used

  • Flow and return on heating or a heat pump: the spread is the figure that matters, not the single temperature. Two clamp-on probes, one device, no time offset.
  • Cylinder stratification: top and bottom of the hot water cylinder — from which the usable reserve can be estimated, which a single reading cannot give.
  • Solar thermal and heat recovery: collector circuit and store, supply air and exhaust air — wherever the plant is controlled on a difference.
  • Two cold rooms on one device: where two rooms adjoin, one transmitter outside and two cables through the seals are enough.
  • Inside and outside the same envelope: cold room wall, greenhouse, livestock housing — the difference shows the heat ingress that is otherwise only estimated.
  • Soil at two depths: surface and root horizon at the same spot, for frost warning and irrigation decisions.
  • Process monitoring with inlet and outlet: heat exchanger, dryer, cooling line — the temperature difference across the run is what describes the process.
  • Large rollouts: one article, one decoder, one spare — and through the D22-LS, D22-NB and D22-CB variants the same measuring technology with a different form of power or radio.
No light, no solar operation. A LoRaWAN uplink costs little energy, so the balance is relaxed — but it stands or falls with where the panel sits. In the shade of a hedge, behind a roof edge or down a shaft it does not carry. Where the light is missing, the battery version D22-LB is the right choice. Two channels are no substitute for two locations. The cables are 1.5 m each and cannot be extended; both measuring points must therefore lie within a metre and a half of the device. Two widely separated points need two devices. ±0.5 °C is the typical tolerance, not the guaranteed one. Dragino explicitly states up to ±2.0 °C as the maximum — and on a differential measurement the two probes’ tolerances can add up in the unfavourable case. Anyone needing a spread accurate to half a degree compares the two probes against each other first. It does not measure humidity. For that the S31B is the right device. And the cell is not rechargeable. At the end of its life it is replaced; anyone wanting to avoid that takes the solar version D22-LS.

That covers the purchase decision. What follows is the depth needed for mounting, integration and operation.

Why a difference has to be handled differently from two values

The commonest reason for two channels on one device is a temperature difference — spread, heat ingress, gradient. The measurement error behaves differently there than on a single reading, and that is regularly overlooked in planning.

Consequence for planning: with two sensors at ±0.5 °C each, the uncertainty of the difference reaches a whole degree in the unfavourable case. If the spread to be measured is five degrees, that is tolerable; at a spread of two degrees — as occurs on a heat pump at part load — it is not. The remedy is simple and costs nothing: hold both probes side by side in the same medium before installation, note the deviation and carry it as a fixed correction in the evaluation. After that the difference is considerably more accurate than the absolute value — the systematic error cancels out.

Assessment from field practice, not a manufacturer statement: with clamp-on probes the installation error almost always exceeds the sensor error. Two probes, one insulated and one not, deliver a spread that says more about the insulation than about the plant. For a differential measurement the rule is therefore: build both measuring points the same way — same material, same heat transfer compound, same insulation, same position around the pipe.

Payload and integration

The readings arrive on FPort 2 in eleven bytes of fixed order: two bytes of battery voltage in millivolts, two bytes of temperature, two unused bytes, one byte with the alarm flag, the operating mode and the state of input PA8, then two further temperature fields of two bytes each. All temperatures are signed with a factor of ten. D20, D20S, D22 and D23 share this layout; the channel a model does not fit reads 0x7FFF. On the D22 that is the third channel, called Black in the manual.

Device status — model (0x19), firmware, frequency band, sub-band, battery — runs separately on FPort 5, and the replayed stored values on FPort 3. The latter each carry a four-byte Unix timestamp.

For the integration that means three things. First: the decoder has to evaluate the port, otherwise status messages land in the time series as implausible readings. Second: 0x7FFF is not a reading but “no probe” — anyone not catching it gets 3276.7 °C into the database, and on the D22 that is guaranteed to happen, because the third channel always answers that way. Third, and unlike the humidity sensors from the same brand: the live message on FPort 2 carries no timestamp; the measurement time is the time of receipt. Only the replayed stored values bring their own time.

One ambiguity we name openly: the shared manual labels the first temperature field “Temp_Red or Temp_White”, depending on the model. Which of the two fields carries the red-ringed and which the white-ringed probe on the D22 does not emerge clearly from it. The assignment should therefore be checked once at commissioning, by taking one probe in hand and watching which channel rises. That is a minute’s work and saves a swapped measurement series.

Solar operation — what carries the balance and what tips it

A LoRaWAN uplink costs little energy: the radio is awake for fractions of a second and then sleeps on at a few microamps. That makes the solar balance here considerably more relaxed than on a cellular device — the daily demand is low enough that even an overcast winter day usually still covers it. The rechargeable 3000 mAh Li-ion cell is not meant as the main store but as a buffer overnight and through spells of bad weather.

Consequence for planning: what decides is not the cell capacity but where the panel sits. Facing south and unshaded all day, the balance carries; in the shade of a hedge, behind a roof edge or down a shaft it does not — and that shows in December, not in June.

Assessment from field practice, not a manufacturer statement: for the solar version Dragino gives neither a battery life nor a minimum irradiation. With two independent variables — location and reporting interval — that is consistent, but it does not help with planning. What is usable is the cell voltage carried in every message: anyone recording it through the first winter knows afterwards whether the site carries, instead of guessing.

Data at a glance

Sensing elements2 × Dallas DS18B20 in stainless steel sleeves, IP65, 1.5 m cable each, marked with a red and a white ring
Temperature−55 … +125 °C per channel · ±0.5 °C typical, up to ±2.0 °C maximum · resolution 0.1 °C
Operating temperature−40 … 85 °C (device)
RadioLoRaWAN 1.0.3, Class A, OTAA · EU868 · up to +22 dBm · sensitivity down to −139 dBm
PayloadFPort 2 readings (11 bytes, two channels used) · FPort 3 stored values with timestamp · FPort 5 device status
ConfigurationLoRaWAN downlink · Bluetooth 5.1 on site · firmware update over the air
Powersolar panel with rechargeable 3000 mAh Li-ion cell · no battery-life figure from the manufacturer
EnclosureIP66 · 200 × 120 × 55 mm · 372 g
VersionsD22-LB LoRaWAN battery · D22-LS LoRaWAN solar · D22-NB NB-IoT · D22-NS NB-IoT solar · D22-CB LTE-M and NB-IoT · D22-CS LTE-M and NB-IoT solar

What the manufacturer does not state: the product photographs show a circular connector between the enclosure and the probe cable, so the probe pair is apparently detachable. Dragino does not say whether the probes are individually replaceable and available as spares — for an application where one sensor is mechanically exposed, that would be the decisive information. Also left open are the diameter and length of the stainless sleeves and a dimensioned drawing. We are asking the manufacturer about both.

+ Mostra altro

Dokumente

Recensioni

Ancora non ci sono recensioni.

Recensisci per primo “Dragino D22-LS LoRaWAN temperature sensor with two stainless steel probes IP66 (868 MHz) — solar”

Details

Generale
Marca
Dragino
Codice produttore
D22-LS
Colore
nero
Interfaccia
LoRa 868MHz
Version des LoRa (Long Range) Low-Power-Wireless-Chipsatzes, der auf verschiedenen Frequenzen arbeitet. Typischerweise für IoT-Anwendungen mit geringem Stromverbrauch und großer Reichweite verwendet.
Connettività
Connettività
LoRaWAN
Long Range Wide Area Network, ein drahtloses Protokoll für Low-Power-Geräte in weiträumigen Netzwerken, ideal für das IoT.
Specifica LoRaWAN
1.0.3
Classe dispositivo
A
Klasse A-Geräte ermöglichen bidirektionale Kommunikation zwischen dem Gerät und dem Netzwerk. Nach jeder Uplink-Übertragung des Geräts sind zwei kurze Downlink-Empfangsfenster geöffnet. Diese Geräte haben die niedrigste Energieeffizienz und sind für Anwendungen geeignet, die keine festgelegten Empfangszeitpunkte erfordern. Beispielsweise könnte ein IoT-Sensor, der sporadisch Temperaturdaten an eine Cloud sendet, ein Klasse A-Gerät sein.
Antenna esterna
sì
Frequenze
EU868
LoRaWAN-Frequenzband für Europa (868 MHz). Verwendet in Ländern wie Deutschland, Frankreich, Großbritannien und den meisten anderen europäischen Ländern.
Alimentazione
Alimentazione
Batterie
,
Solarstrom
Pile incluse
Ja
Numero di pile
2
Tipo di pila
Li-Ion
Pila sostituibile
no
Meccanica/design
Peso del prodotto (g)
372
Larghezza (mm)
120
Lunghezza (mm)
200
Altezza (mm)
55
Codice IP / protezione
IP66
Staubdicht. Schutz gegen starkes Strahlwasser und bei Überflutung. Ein IoT-Sicherheitskamera im Freien könnte diesen Schutz haben.
Intervallo di temperatura
-40 °C bis 85 °C
Informazioni commerciali
Paese d’origine
Cina
Altre caratteristiche
Sensori
temperatura
Luogo d’impiego
interno ed esterno
Server di rete
ChirpStack
,
Swisscom LPN
,
TTN