Dragino D20-CS LTE-M and NB-IoT temperature sensor with 2 m stainless steel probe IP66 (868 MHz) — solar

SKU:3JRJ
Cod. produttore:D20-CS-GE
Marca:Dragino
Categorie:
Sensoren:
Disponibilità CH:
non in magazzino0
Da magazzino esterno:
Tempo di consegnain ca. 20 giorni
Il termine vale a partire da 10 pezzi. Per quantità inferiori chiedeteci. (?)

CHF83.06 IVA escl.

più spese di spedizione

LoRaWAN temperature sensor for outdoor use with a remote stainless steel probe on 2 m of cable: DS18B20 from −55 to +125 °C, ±0.5 °C typical. IP66 enclosure, recording when the network drops, 8500 mAh cell for up to five years. For cold stores, heating systems, compost and water tanks.

! Per utilizzare questo dispositivo serve una rete LoRaWAN. Potete crearla voi stessi con un gateway LoRaWAN, usare la rete LORIOT o TTN, oppure la rete Swisscom LoRaWAN che copre tutta la Svizzera. Tutte queste reti sono acquistabili da noi.
 Aggiungi al confronto

The Dragino D20-CS is the simplest useful outdoor temperature sensor: a rugged DS18B20 in a stainless steel sleeve on two metres of cable, and the rest is radio and battery. Its range runs from −55 to +125 °C and so reaches well beyond what humidity sensors can do — deep freeze at one end, heating flow at the other. The IP66 enclosure stays outside, the probe goes where the measurement is. This version transmits without a gateway over LTE-M or NB-IoT onto the cellular network and is solar powered — the most demanding of the energy budgets, because cellular consumes more than LoRaWAN and the cell holds only 3000 mAh.

  • −55 … 125 °Cprobe range
  • ±0.5 °Ctypical, max. ±2.0 °C
  • 2 mprobe cable
  • IP66enclosure, probe IP65
  • 3000 mAhLi-ion, solar charged

What defines the D20-CS

  • A measuring range that covers most applications: −55 to +125 °C is not a marketing figure but the DS18B20’s range. The same device therefore measures in a deep-freeze store and on a heating return — and that is why this sensor is so often the right choice although it can do nothing but temperature.
  • The probe is stainless steel, not plastic: the sensing element sits in a stainless sleeve rated IP65. It slides into a thermowell, straps to a pipe or pushes into bulk material — and it survives the cleaning that open sensors fail.
  • Two metres of cable separate measurement from radio: the device hangs where it has coverage and stays reachable; the probe goes into the cold room, down the shaft, onto the pipe. On a compact sensor both are in the same place — here they are not.
  • A digital bus, not analogue technology: the DS18B20 delivers a digital value. There is no characteristic curve to store, no line loss to compensate and no calibration at commissioning — unlike PT100s or thermocouples.
  • An alarm flag in every message: a dedicated bit shows whether the value has left a set threshold. Thresholds are set by downlink, and so is the minimum time between two alarm messages — a sensor sitting on a limit therefore does not flood the network.
  • Recording when the network drops: if coverage fails, the device writes timestamped readings to its own memory and sends them on once the network is back. For an evidential series that is the difference between a gap and continuity.
  • Device status travels along: cell voltage, device model, IMEI and serial number sit in the same message as the readings. For a fleet that means the inventory can be kept from the running data stream without querying the device — and the cell voltage doubles as the early warning before a battery change.
  • No battery change planned in: the solar panel charges a rechargeable 3000 mAh Li-ion cell. With sufficient light the replacement cycle disappears — at hard-to-reach measuring points the larger item over the service life. It still supplies the cellular module’s short, high currents.
  • Configuration without a network server: reporting interval and thresholds are set on the device or sent back through your own server. There is no LoRaWAN network server managing downlinks here — that responsibility sits with your platform.
  • No gateway, no network server: the device transmits straight onto the cellular network and sends its data to your endpoint. No device profile, no join, no key management — but a SIM that wants managing.
  • The same electronics, four probe variants: anyone needing a buriable probe takes the D20S; two measuring points on one device, the D22; three, the D23. Decoder and integration stay the same.

Where the D20-CS is used

  • Chilled and frozen stores: device outside, probe inside, cable through the door seal. The radio path does not run through the metal door — the reason cold-store monitoring otherwise has holes. And −55 °C covers deep freeze as well.
  • Heating, heat pumps, solar thermal: flow and return temperature with a pipe clamp probe, without touching the hydraulics.
  • Hot water and legionella checks: the range up to 125 °C covers every cylinder and circulation temperature; the stainless probe fits common thermowells.
  • Compost, silage, bulk material: the probe sits in the heap, the device on a post. Self-heating caught early is the difference between turning the pile and a fire.
  • Greenhouse, livestock housing, polytunnel: temperature in the crop rather than under the roof.
  • Machine and bearing monitoring: the probe at the bearing, the device outside the danger zone.
  • Water tanks and cisterns: the probe hangs in the tank, the device on the lid — the probe’s IP65 is built for that, though continuous operation under water is not specified.
  • Large rollouts: one article, one decoder, one spare — and through the D20-LS, D20-NB and D20-CB variants the same measuring technology with a different form of power or radio.
No light, no solar operation — and here it counts twice. Cellular consumes more than LoRaWAN, and the cell has only 3000 mAh. A panel in shade or down a shaft will not carry that balance through winter. Where the light is missing, the battery version D20-CB is the right choice. Without a SIM and without a server nothing works. This version (order suffix GE) comes without a SIM card. You need an SIM enabled for LTE-M or NB-IoT — not every data card is — and an endpoint for MQTT, TCP or UDP. Cellular costs money continuously. A data charge falls due per device per year; with several devices in one place LoRaWAN with your own gateway is almost always cheaper. ±0.5 °C is the typical tolerance, not the guaranteed one. Dragino explicitly states up to ±2.0 °C as the maximum across the whole range. For trends, threshold monitoring and running a plant that is enough; for an acceptance measurement or a calibration record it is not. Anyone who has to prove half a degree needs a PT100 — for example the LTC1 from the same series. It does not measure humidity. Where humidity is part of the question — storage, room climate, mould risk — the S31B is the right device. The cable is two metres long and fixed. It passes through the gland and cannot be extended; a measuring point further away needs a different arrangement. And the cell is not rechargeable. At the end of its life it is replaced, or the device is; anyone wanting to avoid that takes the solar version D20-LS.

That covers the purchase decision. What follows is the depth needed for mounting, integration and operation.

What ±0.5 °C means in practice

The DS18B20 has been the standard sensor for exactly this class of task for decades, and its tolerance is well documented: in the middle of the range it typically holds half a degree, at the edges of the range considerably less well. Dragino states this correctly as ±0.5 °C typical and up to ±2.0 °C maximum — a detail many suppliers leave out.

Consequence for planning: what decides is whether the application needs an absolute value or a change. A cold chain with a limit at −18 °C does not tolerate half a degree of uncertainty well — there the threshold belongs set conservatively, or the sensor checked against a reference instrument. Compost monitoring, where fifteen degrees of rise is the point, tolerates it easily.

Assessment from field practice, not a manufacturer statement: the larger error usually sits not in the sensor but in the installation. A pipe clamp probe without heat transfer compound and without insulation reads several degrees low depending on room temperature; a probe hanging against the wall of a cold room rather than in the air measures the wall. Anyone who installs it properly gets more out of this sensor than out of a more accurate sensor badly placed.

Payload and integration

Without LoRaWAN the whole apparatus of ports, device profiles and decoders falls away: there is no FPort, no network server and no payload function for anyone to maintain. The device opens a connection to the cellular network and delivers the same values — cell voltage, measured quantities, alarm flag, device identity — straight to your endpoint.

Consequence for the integration: what was the decoder in the network server under LoRaWAN is here the receiver on your side. That is less infrastructure but the same work — the raw format has to be interpreted once. The exact field order is in the manufacturer’s cellular manual, linked under “Documents”; it differs from the LoRaWAN version and belongs held against a real message once at commissioning.

One point regularly overlooked on cellular devices: the device identity comes from the IMEI and serial number, not from a DevEUI. Anyone running a fleet of LoRaWAN and cellular devices together needs a key field that can take both.

No gateway — what that costs and what it saves

LTE-M and NB-IoT use the cellular network that is there anyway. So there is no gateway infrastructure to build, no coverage to plan and no network server to run. In return every device needs a SIM card and a server that accepts the data — the costs do not disappear, they move from the initial investment into running expenses.

The arithmetic that comes first: a single sensor somewhere remote is a clear case for cellular — a gateway for one device never pays. Thirty sensors on one site are an equally clear case for LoRaWAN. The boundary lies, depending on tariffs, somewhere between five and ten devices per site, and it shifts with the question of whether anyone is there to look after a gateway.

Assessment from field practice, not a manufacturer statement: what is regularly underestimated is not the radio technology but the SIM. Many standard data cards are not enabled for LTE-M and NB-IoT at all, and that only shows when the device fails to get onto the network at the site. On top comes administration: a hundred LoRaWAN devices hang on one network server, a hundred NB-IoT devices on a hundred SIM contracts with terms and invoices. That is not a technical but an organisational argument — and on larger fleets it decides more often than range does.

Connecting to your own server

The device speaks MQTT, MQTT over TLS, TCP and UDP. MQTT with TLS is the right choice for most applications: widespread, economical and encrypted. UDP is more economical still and therefore kinder to the battery, but offers no delivery guarantee — usable where individual lost messages are tolerable.

Server, port, credentials and topic are set on the device. There is no network server decoding the payload; the device sends straight to your endpoint. Decoder maintenance falls away, and responsibility for reachability and certificates rests with you.

LTE-M or NB-IoT — what the difference means in practice

Both are narrowband cellular methods for devices that send little data and must last. They differ in three respects that matter in planning. Response time: LTE-M answers in seconds, NB-IoT can take considerably longer depending on the mode — for an alarm message the difference between usable and unusable. Building penetration: NB-IoT is narrower and reaches deeper; it carries in a cellar shaft where LTE-M drops out. Mobility: LTE-M permits a cell change during a connection, NB-IoT does not.

Consequence for planning: the choice is not made once for the whole fleet but per site. That is exactly what a device that can do both is good for — the decision is taken at commissioning and can be corrected later without swapping hardware. The device does not use both at once, however: it works in one mode.

Solar and cellular — the tightest energy budget

Solar and cellular are each manageable on their own; together they are the most demanding combination. A cellular module draws short, high currents when establishing a connection and, over the day, needs considerably more than a LoRaWAN transmitter, and the solar cell has only 3000 mAh, a good third of the lithium primary cell’s capacity. What works effortlessly in summer can tip over in December.

Consequence for planning: the reporting interval is not a comfort parameter here but the decisive lever — and radio quality at the site shifts the balance again, because a device at the edge of coverage transmits with more power and stays awake longer. Anyone combining solar and cellular plans the interval around winter.

Assessment from field practice, not a manufacturer statement: for this version Dragino gives neither a battery life nor a minimum irradiation — consistent, with three independent variables. What is usable instead is the cell voltage that comes with every message: anyone watching it through the first winter knows afterwards whether the site carries.

Data at a glance

Sensing element1 × Dallas DS18B20 in a stainless steel sleeve, IP65, 2 m cable
Temperature−55 … +125 °C · ±0.5 °C typical, up to ±2.0 °C maximum · resolution 0.1 °C
Operating temperature−40 … 85 °C (device)
RadioQuectel BC660K-GL · LTE-M (CAT-M1) and NB-IoT
SIMGE version: without SIM · 1T version: 1NCE SIM, 500 MB over 10 years
Payloadraw format straight to your own endpoint · no FPort, no network-server decoder · field order in the manufacturer’s cellular manual
Configurationon the device or through your own server’s return channel · Bluetooth 5.1 on site · firmware update over the air
Powersolar panel with rechargeable 3000 mAh Li-ion cell · no battery-life figure from the manufacturer
EnclosureIP66 · 200 × 120 × 55 mm · 372 g
VersionsD20-LB LoRaWAN battery · D20-LS LoRaWAN solar · D20-NB NB-IoT · D20-NS NB-IoT solar · D20-CB LTE-M and NB-IoT · D20-CS LTE-M and NB-IoT solar

What the manufacturer does not state: Dragino does not name the probe cable’s material for the D20 — on the buriable D20S it is explicitly TPE, on the D20 it is left open. A dimensioned drawing of the probe is also missing; the diameter and length of the stainless sleeve appear neither on the product page nor in the manual. Anyone wanting to fit an existing thermowell should ask for the dimensions before ordering — we will add them at the first goods receipt.

+ Mostra altro

Dokumente

Recensioni

Ancora non ci sono recensioni.

Recensisci per primo “Dragino D20-CS LTE-M and NB-IoT temperature sensor with 2 m stainless steel probe IP66 (868 MHz) — solar”

Details

Generale
Marca
Dragino
Codice produttore
D20-CS-GE
Colore
nero
Connettività
Connettività
LTE-M
Auch bekannt als LTE Cat M1 oder eMTC.Long Term Evolution for Machines, eine Technologie für Maschine-zu-Maschine (M2M) Kommunikation in LTE-Netzwerken.
,
NB-IoT
NarrowBand Internet of Things, eine Low-Power-Wide-Area-Technologie, die speziell für das IoT entwickelt wurde, um eine größere Abdeckung mit geringerem Stromverbrauch zu ermöglichen.
Antenna esterna
sì
Alimentazione
Alimentazione
Batterie
,
Solarstrom
Pile incluse
Ja
Numero di pile
1
Tipo di pila
Li-Ion
Pila sostituibile
no
Meccanica/design
Peso del prodotto (g)
372
Larghezza (mm)
120
Lunghezza (mm)
200
Altezza (mm)
55
Codice IP / protezione
IP66
Staubdicht. Schutz gegen starkes Strahlwasser und bei Überflutung. Ein IoT-Sicherheitskamera im Freien könnte diesen Schutz haben.
Intervallo di temperatura
-40 °C bis 85 °C
Schede
Nano-SIM (4FF)
Informazioni commerciali
Paese d’origine
Cina
Altre caratteristiche
Sensori
temperatura
Luogo d’impiego
interno ed esterno