The Dragino S31B-LB measures temperature and humidity where it hangs — sensor and radio are one piece. The Sensirion SHT31 sits in a condensation-proof sleeve directly on the enclosure: no cable to route, no second mounting point. At ±0.2 °C and ±2 %RH it is markedly tighter than the usual room sensors, and the 8500 mAh cell carries it for years. The IP66 enclosure is built for outdoors, not merely tolerated there — which makes it the outdoor climate sensor you screw to a wall and forget for five years.
- ±0.2 °Caccuracy, 0 … 90 °C
- ±2 %RHhumidity, whole range
- IP66enclosure
- −40 … 85 °Coperating range
- 8500 mAhLi-SOCl₂ cell
What defines the S31B-LB
- One piece instead of two mounting points: the sensor sits in a sleeve attached directly to the enclosure. No cable to route, clamp or lead through a seal — mounting is one screwed fixing and done. Across a fleet of outdoor measuring points that is the difference between twenty minutes and five per device.
- A Sensirion SHT31, not a house brand: the sensor fitted has a public datasheet and behaviour documented over years. ±0.2 °C and ±2 %RH are not marketing but the component’s specification — and they sit a class above what simple room sensors deliver.
- The drift is stated, not glossed over: the manufacturer gives less than 0.03 °C and less than 0.25 %RH deviation per year. That is the figure which decides, over five years, whether a measurement series stays comparable — and the one that is simply missing from most cheap sensors.
- Condensation-proof, not merely splash-proof: the sleeve lets humidity through but not water. That is exactly where open sensors fail outdoors: after the first condensation cycle they read permanently wrong.
- The timestamp comes from the device: every message carries a Unix time from the sensor, not just the network server’s time of receipt. If delivery is delayed the series still stays chronologically correct — the precondition for it to serve as evidence.
- An alarm flag in every message: a dedicated bit shows whether the value has left a set threshold. The evaluation therefore does not have to check thresholds itself, and an alarm is not lost if processing falls behind.
- Recording when the network drops: if coverage fails, the device writes the readings to its own memory and sends them on once the network is back. For an evidential series that is the difference between a gap and continuity.
- Device status on its own port: model, firmware version, frequency band and battery arrive on FPort 5, separate from the readings on FPort 2. For a fleet that means the inventory can be queried without searching the measurement database.
- A large cell, soberly reckoned: 8500 mAh of Li-SOCl₂ is three times that of a common room sensor, and because no external probe has to be powered before each reading, the budget here works out slightly better still than on the sibling device with a cable. The manufacturer quotes up to five years.
- Configuration over the air: reporting interval and thresholds are set by downlink. The device can also be configured on site over Bluetooth 5.1 and its firmware updated wirelessly — a device on a façade stays where it is.
- Not tied to a platform: LoRaWAN 1.0.3, Class A, OTAA. Runs on TTN, ChirpStack and the Swisscom LPN with the same device profile and the same decoder.
- Two forms of power, one article: where no battery change is wanted, the same device comes as the S31B-LS with a solar panel and a rechargeable cell. The measuring and radio sections are identical, the integration stays the same.
Where the S31B-LB is used
- Outdoor climate on buildings: IP66 and a condensation-proof sleeve allow façade mounting; the operating range runs from −40 to 85 °C. This device’s classic application.
- Unheated halls, barns, storage sheds: one device, one screw, no wiring — and reachable over radio even where no line runs.
- Stores with humidity limits: paper, timber, electronics, animal feed. ±2 %RH is accurate enough to prove a limit and not merely assert it.
- Greenhouse and polytunnel: the sensor hangs in the crop along with the device. Condensation-proof, so still able to measure after misting.
- Building sites and temporary measuring points: mounted in minutes, removed just as fast, nothing to route.
- Plant rooms and service risers: where the measuring point and the device location coincide, the compact form saves the second fixing.
- Evidence towards third parties: thanks to the device’s own timestamp and the replay from memory the series stays continuous and chronological.
- Large rollouts: one article, one decoder, one spare — and through the S31B-LS variant the solar-powered version as well, with no new integration.
That covers the purchase decision. What follows is the depth needed for mounting, integration and operation.
Why the mounting location becomes a measured quantity here
On a device with a remote probe, the question “where do I measure” is separate from the question “where does the transmitter hang”. On the S31B the two coincide, and so the mounting location becomes part of the measurement. That is not a fault but a property to account for in planning — and one regularly overlooked in practice.
Consequence for planning: a black plastic enclosure in direct sun becomes warmer than the air it is meant to measure; depending on irradiation and wind that is several degrees. For outdoor air temperature the device therefore belongs on the north side, under a roof overhang or inside a radiation shield. The same applies in reverse to heat sources indoors: a device above a radiator or beside a switch cabinet measures the cabinet as well.
Assessment from field practice, not a manufacturer statement: the S31B shares this limitation with every compact sensor, and it is the real reason the cabled version exists at all. Anyone needing absolute outdoor air temperatures — for evidence, not for a trend — should plan for a radiation shield; anyone following trends and threshold breaches in a sheltered mounting position does not need one. Dragino makes no statement about sensitivity to radiation; on a device that hangs in arbitrary places that is hard to quantify anyway.
Payload and integration
The readings arrive on FPort 2 in a fixed order: two bytes of battery voltage in millivolts, four bytes of Unix timestamp, one byte with the alarm flag, the operating mode and the state of input PA8, then two bytes of temperature as a signed value with a factor of ten and two bytes of humidity with a factor of ten. Device status — model, firmware, frequency band, sub-band, battery — runs separately on FPort 5, and the replayed stored values on FPort 3.
For the integration that means two things. First: the decoder has to evaluate the port, otherwise status messages land in the time series as implausible readings — an error that only shows up when somebody analyses the data. Second: the supplied timestamp should be used as the measurement time, not the time of receipt. With LoRaWAN there may be minutes between measurement and delivery, and hours for replayed stored values; for an evidential series that is the difference between right and nearly right.
Data at a glance
| Sensor | Sensirion SHT31 in a watertight, condensation-proof sleeve, directly on the enclosure |
| Temperature | sensor −40 … +80 °C · ±0.2 °C in the range 0 … 90 °C · resolution 0.1 °C · long-term drift < 0.03 °C/yr |
| Humidity | 0 … 99.9 %RH · ±2 %RH across the whole range · resolution 0.01 %RH · long-term drift < 0.25 %RH/yr |
| Operating temperature | −40 … 85 °C |
| Radio | LoRaWAN 1.0.3, Class A, OTAA · EU868 · up to +22 dBm · sensitivity down to −139 dBm |
| Payload | FPort 2 readings · FPort 3 stored values · FPort 5 device status |
| Configuration | LoRaWAN downlink · Bluetooth 5.1 on site · firmware update over the air |
| Power | 8500 mAh Li-SOCl₂, not rechargeable · quiescent current 5 µA at 3.3 V · manufacturer: up to 5 years |
| Enclosure | IP66 · 200 × 120 × 55 mm |
| Versions | S31B-LB LoRaWAN battery · S31B-LS LoRaWAN solar · S31B-NB NB-IoT · S31B-NS NB-IoT solar · S31B-CB LTE-M and NB-IoT · S31B-CS LTE-M and NB-IoT solar |
On the measuring range: the manufacturer gives −40 to +80 °C for the sensor and an operating range of −40 to 85 °C for the device. The accuracy figure of ±0.2 °C refers to 0 to 90 °C and so reaches beyond the sensor’s range — that is the SHT31 component’s specification, not the finished device’s. Outside 0 to 80 °C the tolerance is larger; how much larger, Dragino does not say. For sub-zero temperatures one should therefore not count on two tenths of a degree, but hold the setup against a reference instrument once.
On the weight: the manufacturer states 370 g on the product page — the same figure as for the sibling device with three metres of probe cable, which is implausible for a device without one. The price list gives 230 g for the shipping unit. We therefore state no device weight and will add it after the first goods receipt.


Recensioni
Ancora non ci sono recensioni.