The Dragino DDS75-CS is the solar version of the DDS75-CB and measures distance and level without contact using ultrasound and transmits without a gateway straight onto the cellular network — either over LTE-M or NB-IoT. Which of the two carries at a particular measuring point is rarely known in advance; a device that can do both takes that uncertainty out of the planning. Measurement happens from 280 millimetres to 7.5 metres, with temperature compensation and without touching the medium at all. That is precisely its argument: it works above sewage, sludge, bulk solids and aggressive liquids where an immersed probe corrodes or fouls. The measuring head sits on 25 centimetres of cable and screws into the cover or the shaft pipe, while the electronics stay beside it in the IP66 enclosure. What you need to know before buying is the 40-degree beam angle — it decides whether the measurement works in the shaft or fails on the wall.
- 0.28 … 7.5 mmeasuring range
- ±1 cm + 0.3 %accuracy
- 40°beam angle
- no gatewaystraight onto cellular
- 3000 mAhLi-ion, solar charged
What defines the DDS75-CS
- No contact with the medium: the sound travels through air. Nothing sits in the liquid, fouls, corrodes or has to be cleaned — the reason ultrasound is the first choice in sewage, slurry and grit traps.
- Temperature compensation built in: the speed of sound in air depends on temperature, and noticeably so: roughly five per cent between 0 and 30 °C. Without compensation a level reading would not be the same in summer and winter. The device takes it out.
- Accuracy that grows with distance: ±1 cm plus 0.3 per cent of the measured distance. At one metre that is about 1.3 cm, at seven metres about 3.1 cm. This form of statement is more honest than a fixed number of centimetres, because it reflects how the method behaves.
- Remote measuring head: 25 centimetres of cable between electronics and transducer. The head screws in, the enclosure stays accessible — nobody has to climb into the shaft to change the battery.
- IP66 and −40 to 85 °C: the device is built for outdoor mounting and unheated shafts, not merely permitted for them.
- No battery change planned in: the solar panel charges a rechargeable 3000 mAh Li-ion cell. With sufficient light the replacement cycle disappears — at hard-to-reach measuring points the larger item over the service life. It still supplies the cellular module’s short, high currents.
- Configuration without a network server: reporting interval and thresholds are set on the device or sent back through your own server. There is no LoRaWAN network server managing downlinks here — that responsibility sits with your platform.
- No gateway, no network server: the device transmits straight onto the cellular network and sends its data to your endpoint. No device profile, no join, no key management — but a SIM that wants managing.
- The same form in four power versions: battery, solar, NB-IoT and LTE-M — measuring section and mounting stay identical, the decision follows the site and the infrastructure.
- Explicitly named for sewage by the manufacturer: sewer, grit trap and bottom water level appear in its own application list. For a device in this price class that is not a given.
Where the DDS75-CS is used
- Level in cisterns and rainwater tanks: the classic application — non-contact, low-maintenance, and the reading is directly the distance to the surface.
- Sewage, sewers and grit traps: media in which every immersed sensor becomes a maintenance item.
- Retention basins and flood monitoring: level over time, even with foam and floating debris on the surface — with the limitations set out below in the technical section.
- Bulk solids in silos and hoppers: wood chips, pellets, granulate. Cone formation has to be allowed for, because the sensor sees the highest point of the cone.
- Waste containers and collection points: named by the manufacturer itself — fill level as the basis for emptying on demand rather than on fixed rounds.
- Parking and occupancy: distance measurement as presence detection above a bay.
- Slurry and manure pits: aggressive atmosphere, no contact with the medium, mounting in the cover.
- Large rollouts: one device type for water, sludge and bulk solids, one mounting method, one decoder — the difference between a range and a single part number.
That covers the purchase decision. What follows is the depth needed for mounting, radio planning and operation.
Planning the measuring cone properly
Ultrasound spreads as a cone, not as a beam. The 40 degrees of beam angle give the diameter of the insonified area directly: it is about 0.73 times the distance. That is the figure to plan the installation with — not the measuring range.
| 1 m distance | about 0.73 m cone diameter |
| 2 m distance | about 1.5 m |
| 3 m distance | about 2.2 m |
| 5 m distance | about 3.6 m |
| 7.5 m distance | about 5.5 m |
Consequence for mounting: in a standard shaft one metre across, the cone is wider than the shaft from about 1.4 metres depth. Mounted centrally the measurement still remains usable, because the strongest echo comes from the cone axis — but every ladder, every pipe mouth and every ledge on the wall produces a spurious echo. The rule of thumb: central, plumb, and everything with an edge kept out of the cone.
Assessment from field practice, not a manufacturer statement: the commonest mounting error on ultrasonic level measurements is not a tilted installation but proximity to the wall. A sensor sitting ten centimetres from the shaft edge delivers plausible values for months and then jumps to a fixed value as the level falls — that is the moment it receives the wall echo more strongly than the water echo. Anyone who watches the measuring point over one complete fill-and-empty cycle spots it immediately; anyone checking only snapshots never finds it.
What the accuracy figure means in practice
±(1 cm + 0.3 % of the measured distance) is a composite figure: a fixed part from the time measurement and a proportional part from the uncertainty in the speed of sound. In practice the absolute deviation grows with distance while the relative one shrinks — at 30 cm, 1.1 cm is almost four per cent; at 7 m, 3.1 cm is less than half a per cent.
For a volume calculation the geometry of the vessel therefore matters more than the last centimetre: in a flat, wide cistern one centimetre of level deviation amounts to many litres; in a slender shaft, to few. Anyone wanting to report volume in litres should calibrate the conversion against two known levels rather than relying on the vessel’s nominal dimensions.
No gateway — what that costs and what it saves
LTE-M and NB-IoT use the cellular network that is there anyway. So there is no gateway infrastructure to build, no coverage to plan and no network server to run. In return every device needs a SIM card and a server that accepts the data — the costs do not disappear, they move from the initial investment into running expenses.
The arithmetic that comes first: a single sensor somewhere remote is a clear case for cellular — a gateway for one device never pays. Thirty sensors on one site are an equally clear case for LoRaWAN. The boundary lies, depending on tariffs, somewhere between five and ten devices per site, and it shifts with the question of whether anyone is there to look after a gateway.
Assessment from field practice, not a manufacturer statement: what is regularly underestimated is not the radio technology but the SIM. Many standard data cards are not enabled for LTE-M and NB-IoT at all, and that only shows when the device fails to get onto the network at the site. On top comes administration: a hundred LoRaWAN devices hang on one network server, a hundred NB-IoT devices on a hundred SIM contracts with terms and invoices. That is not a technical but an organisational argument — and on larger fleets it decides more often than range does.
Connecting to your own server
The device speaks MQTT, MQTT over TLS, TCP and UDP. MQTT with TLS is the right choice for most applications: widespread, economical and encrypted. UDP is more economical still and therefore kinder to the battery, but offers no delivery guarantee — usable where individual lost messages are tolerable.
Server, port, credentials and topic are set on the device. There is no network server decoding the payload; the device sends straight to your endpoint. Decoder maintenance falls away, and responsibility for reachability and certificates rests with you.
LTE-M or NB-IoT — what the difference means in practice
Both are narrowband cellular methods for devices that send little data and must last. They differ in three respects that matter in planning. Response time: LTE-M answers in seconds, NB-IoT can take considerably longer depending on the mode — for an alarm message the difference between usable and unusable. Building penetration: NB-IoT is narrower and reaches deeper; it carries in a cellar shaft where LTE-M drops out. Mobility: LTE-M permits a cell change during a connection, NB-IoT does not.
Consequence for planning: the choice is not made once for the whole fleet but per site. That is exactly what a device that can do both is good for — the decision is taken at commissioning and can be corrected later without swapping hardware. The device does not use both at once, however: it works in one mode.
Solar and cellular — the tightest energy budget
Solar and cellular are each manageable on their own; together they are the most demanding combination. A cellular module draws short, high currents when establishing a connection and, over the day, needs considerably more than a LoRaWAN transmitter, and the solar cell has only 3000 mAh, a good third of the lithium primary cell’s capacity. What works effortlessly in summer can tip over in December.
Consequence for planning: the reporting interval is not a comfort parameter here but the decisive lever — and radio quality at the site shifts the balance again, because a device at the edge of coverage transmits with more power and stays awake longer. Anyone combining solar and cellular plans the interval around winter.
Assessment from field practice, not a manufacturer statement: for this version Dragino gives neither a battery life nor a minimum irradiation — consistent, with three independent variables. What is usable instead is the cell voltage that comes with every message: anyone watching it through the first winter knows afterwards whether the site carries.
Data at a glance
| Method | ultrasound with temperature compensation, non-contact |
| Measuring range | 280 … 7500 mm (manufacturer’s figure for flat objects) |
| Accuracy | ±(1 cm + distance × 0.3 %) |
| Beam angle | 40° |
| Measuring head | remote on 25 cm of cable, screw-in |
| Radio | Quectel BC660K-GL · LTE-M (CAT-M1) and NB-IoT |
| SIM | GE version: without SIM · 1T version: 1NCE SIM, 500 MB over 10 years |
| Power | solar panel with rechargeable 3000 mAh Li-ion cell · no battery-life figure from the manufacturer |
| Enclosure | IP66 · operating temperature −40 … 85 °C |
| Shipping unit | 150 × 120 × 55 mm, 220 g |
| Versions | DDS75-CS solar · DDS75-CB battery · DDS75-LB as LoRaWAN |
On the state of the sources: for the LTE-M version of the DDS75 Dragino provides no product page of its own; only the NB-IoT version is documented. The classification as an LTE-M and NB-IoT device comes from the reseller price list, the BC660K-GL radio module from the NB version’s page. The exact band lists per method appear nowhere for this model — they are likely to match those of the identically equipped S31-CB, but we have not carried them over. To be asked of the manufacturer.
What the manufacturer does not state: the dead zone is not named explicitly; in practice it follows from the lower range limit of 280 mm. Resolution, enclosure dimensions without packaging and a mounting method do not appear on the product page either. To be added at the first goods receipt.

Recensioni