Dragino SE01-NB NB-IoT soil sensor for moisture, temperature and conductivity (without SIM)

SKU:3JQH
Cod. produttore:SE01-NB-GE
Marca:Dragino
Categorie:
Sensoren:
Disponibilità CH:
non in magazzino0
Da magazzino esterno:
Tempo di consegnain ca. 20 giorni
Il termine vale a partire da 10 pezzi. Per quantità inferiori chiedeteci. (?)

CHF145.97 IVA escl.

più spese di spedizione

NB-IoT soil sensor measuring water content, soil temperature and electrical conductivity. Conductivity reveals the salt and nutrient content of the soil solution — only together with water content does the decisive question emerge: can the plant actually take that water up? ±3 % up to 53 % V/V, 0…20,000 µS/cm, IP66, 8500 mAh cell for up to five years.

! Per utilizzare questo dispositivo serve una rete LoRaWAN. Potete crearla voi stessi con un gateway LoRaWAN, usare la rete LORIOT o TTN, oppure la rete Swisscom LoRaWAN che copre tutta la Svizzera. Tutte queste reti sono acquistabili da noi.
 Aggiungi al confronto

The Dragino SE01-NB measures three quantities in the soil at once: water content, temperature and electrical conductivity. The third is the reason to choose this device over a plain moisture probe — it shows the salt and nutrient content of the soil solution and therefore whether a plant can take up the water that is there. High water content together with high conductivity means drought stress despite damp earth, and a moisture probe alone does not show that. The probe is buried, the IP66 enclosure stays above ground, and the 8500 mAh cell carries the device for years. This version transmits without a gateway over NB-IoT straight onto the cellular network — in return it needs a SIM card and a server that accepts the data.

  • 3 quantitiesmoisture, temperature, conductivity
  • ±3 %water content up to 53 % V/V
  • 0 … 20,000 µS/cmconductivity
  • ±0.3 °Csoil temperature, −10 … 50 °C
  • IP66enclosure

What defines the SE01-NB

  • Conductivity is what makes the moisture reading meaningful: water alone does not say whether the plant can take it up. When conductivity rises — through fertilising, salt ingress or evaporation — water is drawn osmotically away from the root zone. Only both values together show the real state.
  • The moisture measurement is temperature- and conductivity-compensated: the FDR method responds to both disturbances. Dragino takes them out, and that is exactly what distinguishes a soil sensor from a cheap resistive probe whose reading wanders with salinity.
  • Temperature via an RTD element: better than 0.3 °C between −10 and 50 °C, which is precisely where soil biology and germination happen. Beyond that it stays under 0.6 °C.
  • Resolution far below the tolerance: 0.01 V/V % for water content, 0.01 °C for temperature, 1 µS/cm for conductivity. For absolute statements the tolerance applies — for changes at the same site the resolution does, and that is the more relevant figure for irrigation control.
  • The conductivity range reaches into saline soil: 20,000 µS/cm also covers substrate culture and salt-affected sites, where horticultural probes have long since run out of scale.
  • Device above, probe below: the electronics stay accessible, only the probe goes into the ground. A battery change therefore means no digging.
  • IP66 and −40 to 85 °C: built for year-round outdoor service, not merely permitted for it.
  • A large cell, soberly calculated: 8500 mAh of Li-SOCl₂, quoted by the manufacturer at up to five years — for three quantities that each cost current per reading, a more honest figure than the ten-year promises of simple probes.
  • No gateway, no network server: the device transmits straight onto the cellular network and sends its data to your endpoint. No device profile, no join, no key management — but a SIM that wants managing.
  • Configuration without a network server: reporting interval and thresholds are set on the device or sent back through your own server. There is no LoRaWAN network server managing downlinks here — that responsibility sits with your platform.

Where the SE01-NB is used

  • Irrigation control in field crops: watering follows the water content of the root zone rather than the calendar — the application that pays for itself fastest.
  • Greenhouse and substrate culture: here conductivity is the governing variable: it shows the substrate salting up long before the plant shows symptoms.
  • Orchards and viticulture: controlled drought stress is a quality tool — it can only be managed if the water content of the rooting horizon is known.
  • Sports turf and golf courses: even moisture across the area, with conductivity as an indication of fertiliser movement.
  • Urban trees: street trees suffer from de-icing salt; conductivity in the root zone makes that measurable rather than suspected.
  • Slope monitoring and soil mechanics: water content as an input for assessing the risk of slippage.
  • Trials and evidence keeping: three quantities with a time series at a defined depth, traceable over years.
  • Large rollouts: one device type, one mounting method, one decoder — and through the solar, NB-IoT and LTE-M versions also for sites without radio infrastructure of their own.
Without a SIM and without a server nothing works. This version (order suffix GE) comes without a SIM card. You need an NB-IoT-capable SIM — not every data card is — and an endpoint for MQTT, TCP or UDP. Cellular costs money continuously. A data charge falls due per device per year; with several devices in one place LoRaWAN with your own gateway is almost always cheaper. Calibration depends on the soil type — and Dragino does not agree with itself here. The feature list states a factory calibration for mineral soils, while the FAQ on the same page speaks of saline-alkali and loamy soil. Both stand side by side without being reconciled. In practice that means: on a different soil — peat, high humus content, very sandy — the absolute values are not usable without recalibration. Dragino supplies a formula for that, applied on the platform. For trends this is immaterial, for absolute values it is not. Anyone who only wants to know whether it is drying out can start straight away. Anyone wanting to report litres per square metre or control against a limit calibrates first. Installation matters as much. An air gap beside the probe distorts the reading more than any tolerance in the datasheet — the soil has to sit tight against it. And three quantities cost current. The five years apply to a restrained reporting interval; anyone measuring every quarter hour calculates differently.

That covers the purchase decision. What follows is the depth needed for installation, analysis and operation.

What FDR measures — and what follows from it

The method is called Frequency Domain Reflectometry. What is measured is not water but the dielectric constant of the soil. Water has about 80 of it, air 1, mineral soil constituents between 3 and 7 — water content therefore dominates the signal to such a degree that it can be inferred reliably. That is the method’s strength and at the same time the reason for its quirks.

First, the relationship depends on the soil type. The same dielectric constant means a different water content in peat than in sand, because the solid matrix differs. Hence the factory calibration to one soil type and the formula for deviating soils. Second, salt interferes. Dissolved ions raise the apparent permittivity; without compensation a fertilised soil would appear wetter than it is. That is exactly why this device measures conductivity anyway and takes it out. Third, the probe only measures its immediate surroundings — a few centimetres around the rods. A cavity beside it therefore weighs heavily.

Assessment from field practice, not a manufacturer statement: the commonest installation error is drilling too large a hole and backfilling it loosely. The probe then sits in loosened soil that holds water differently from the undisturbed ground right next to it — the series is consistent with itself, but it describes the hole and not the field. Better is a slit into which the probe’s three tines are pressed, followed by firm hand compaction of the soil. The probe sits at the end of a cable several metres long, so the device can be mounted well away from it — Dragino does not state the exact cable length, however. Anyone comparing across several sites should also record the installation depth; ten centimetres of difference shifts the curve more than any device tolerance.

Reading conductivity correctly

What is measured is the conductivity of the soil as a whole — solids, water and air together. That is not the same as the conductivity of the soil solution, which is what matters agronomically, and the two are linked through water content: the same salinity in the water gives a lower overall figure in dry soil, because there is less conducting liquid.

Consequence for analysis: conductivity rising while water content falls is the normal case during drying out and not an alarm. It becomes interesting when conductivity rises while water content stays level or increases — then salt is being added, from fertiliser, de-icing salt or saline irrigation water. The rule is therefore never to look at the two curves separately, but overlaid.

No gateway — what that costs and what it saves

NB-IoT uses the cellular network that is there anyway. So there is no gateway infrastructure to build, no coverage to plan and no network server to run. In return every device needs a SIM card and a server that accepts the data — the costs do not disappear, they move from the initial investment into running expenses.

The arithmetic that comes first: a single sensor somewhere remote is a clear case for cellular — a gateway for one device never pays. Thirty sensors on one site are an equally clear case for LoRaWAN. The boundary lies, depending on tariffs, somewhere between five and ten devices per site, and it shifts with the question of whether anyone is there to look after a gateway.

Assessment from field practice, not a manufacturer statement: what is regularly underestimated is not the radio technology but the SIM. Many standard data cards are not enabled for NB-IoT at all, and that only shows when the device fails to get onto the network at the site. On top comes administration: a hundred LoRaWAN devices hang on one network server, a hundred NB-IoT devices on a hundred SIM contracts with terms and invoices. That is not a technical but an organisational argument — and on larger fleets it decides more often than range does.

Connecting to your own server

The device speaks MQTT, MQTT over TLS, TCP and UDP. MQTT with TLS is the right choice for most applications: widespread, economical and encrypted. UDP is more economical still and therefore kinder to the battery, but offers no delivery guarantee — usable where individual lost messages are tolerable.

Server, port, credentials and topic are set on the device. There is no network server decoding the payload; the device sends straight to your endpoint. Decoder maintenance falls away, and responsibility for reachability and certificates rests with you.

Data at a glance

Water content0 … 100.00 V/V % · resolution 0.01 · ±3 % up to 53 %, ±5 % above · FDR with temperature and conductivity compensation
Soil temperature−40.00 … 85.00 °C · resolution 0.01 °C · better than 0.3 °C from −10 to 50 °C, otherwise better than 0.6 °C · RTD
Conductivity0 … 20,000 µS/cm at 25 °C · resolution 1 µS/cm · 2 % of full scale · temperature compensated
RadioNB-IoT via Quectel BC660K-GL · B1/B2/B3/B4/B5/B8/B12/B13/B17/B18/B19/B20/B25/B28/B66/B70/B85 in H-FDD
ProtocolsMQTT · MQTT over TLS · TCP · UDP
SIMGE version: without SIM · nano-SIM slot · 1T version: 1NCE SIM, 500 MB over 10 years
Power8500 mAh Li-SOCl₂, not rechargeable · manufacturer: up to 5 years
EnclosureIP66 · 195 × 125 × 55 mm · 420 g · operating temperature −40 … 85 °C
VersionsSE01-NB battery · SE01-LS solar · SE01-NB NB-IoT · SE01-CB LTE-M and NB-IoT

What the manufacturer does not state: probe material, probe length and cable length do not appear on the product page. For planning the installation those are exactly the figures needed — to be added at the first goods receipt or asked of the manufacturer.

About the predecessor: we have carried the Dragino LSE01 since 2026, which measures the same three quantities. It no longer appears in Dragino’s current reseller price list; the SE01 is its successor and measures moisture and conductivity more tightly. Existing LSE01 installations are unaffected — the payload is not the same, so swapping one in the field requires a change in the decoder.

+ Mostra altro

Dokumente

Recensioni

Ancora non ci sono recensioni.

Recensisci per primo “Dragino SE01-NB NB-IoT soil sensor for moisture, temperature and conductivity (without SIM)”

Details

Generale
Marca
Dragino
Codice produttore
SE01-NB-GE
Connettività
Connettività
NB-IoT
NarrowBand Internet of Things, eine Low-Power-Wide-Area-Technologie, die speziell für das IoT entwickelt wurde, um eine größere Abdeckung mit geringerem Stromverbrauch zu ermöglichen.
Alimentazione
Alimentazione
Batterie
Pile incluse
Ja
Numero di pile
1
Tipo di pila
Li-SOCL₂
Die Li-SOCl₂-Batterie ist ein hochleistungsfähiger Energiespeicher, der Lithium (Li) und Thionylchlorid (SOCl₂) verwendet. Sie zeichnet sich durch eine hohe Energiedichte, lange Lagerfähigkeit und eine breite Betriebstemperaturbereich aus, was sie ideal für IoT-Geräte macht, die eine langanhaltende, zuverlässige Energiequelle benötigen. Im Kontext von IoT definiert sie die Fähigkeit, Geräte über längere Zeiträume autark betreiben zu können, selbst in anspruchsvollen Umgebungsbedingungen.
Meccanica/design
Peso del prodotto (g)
420
Larghezza (mm)
125
Lunghezza (mm)
195
Altezza (mm)
55
Codice IP / protezione
IP66
Staubdicht. Schutz gegen starkes Strahlwasser und bei Überflutung. Ein IoT-Sicherheitskamera im Freien könnte diesen Schutz haben.
Intervallo di temperatura
-40 °C bis 85 °C
Schede
Nano-SIM (4FF)
Informazioni commerciali
Paese d’origine
Cina
Altre caratteristiche
Sensori
umidità del suolo
,
temperatura del suolo
,
conducibilità elettrica
Autonomia
3-5 Jahre
Luogo d’impiego
interno ed esterno