The WisGate Edge Pro RAK7289CV2 is the outdoor gateway for sites where there is neither a network nor a power socket. It receives on eight channels with the SX1303 core, reaches the internet over mobile and can be powered from a solar panel. Two things separate it from the cheaper Edge Prime: the housing is sealed to IP67 rather than IP65, and the antennas for LTE, WiFi and GPS sit inside the enclosure rather than outside. Fewer penetrations means fewer places where water eventually gets in — on a device standing on a mast in the open, that is the real difference.
- IP67sealed even against temporary immersion
- 8 channelsSemtech SX1303
- solaroff-grid operation possible
- LTE · PoEbackhaul and power, one cable each
What sets the Edge Pro apart
- It manages without infrastructure: mobile for the backhaul, solar for the power — that keeps a site running where neither a network cable nor a socket exists. This is the constellation the device is built for.
- Fewer penetrations, less risk: the LTE, WiFi and GPS antennas are housed inside the enclosure. Every antenna penetration in the open is a potential leak in the long run; this housing has considerably fewer of them.
- IP67 instead of IP65: sealed not only against jets of water but against temporary immersion. For sites with snow load, standing water or pressure washing nearby, that is the relevant difference.
- Network server on board: register sensors directly on the gateway and collect the data over MQTT — without an external platform. Running against The Things Stack or ChirpStack remains possible.
- Losing nothing: in packet forwarder mode the gateway buffers received frames for as long as the network server is unreachable. With a mobile backhaul that occasionally drops out at remote sites, that counts double.
- Three routes to power: 12 V DC, PoE per 802.3af or solar at 12 V. On top of that comes the connection to the manufacturer’s battery solution for genuine off-grid operation.
- Remotely manageable: configuration, firmware and monitoring run centrally through WisDM. On a device mounted on a mast that is not a convenience but a precondition.
Where it is used
- Sites without power and network: field, alpine pasture, forest, landfill, shoreline — anywhere a supply line would be disproportionate.
- Water and wastewater: pumping stations, reservoirs, treatment basins. A damp environment and pressure cleaning argue for IP67.
- Agriculture across large areas: one solar-powered gateway on a mast covers what would otherwise need several sites.
- Construction sites and temporary installations: set up, connect over LTE, take away when the project ends.
- Coverage for municipalities: elevated mounting at one point instead of scattered indoor devices.
- Redundancy with a separate backhaul: as a second gateway alongside a wired one — if the line fails, mobile carries on.
That settles the selection. What follows is the depth for planning and installation.
What off-grid operation really demands
A solar-powered gateway is rarely sized on summer performance but on the worst week of the year. What matters is not how much the panel delivers in July but how long the battery carries the device in December in fog. A gateway has no sleep mode like a sensor — it runs continuously, because it has to be ready to receive at any time. That makes sizing both simpler and more expensive: consumption is constant, and the reserve has to bridge several low-yield days.
Two things from practice. First: the panel belongs steeper than you would think — a steep mounting yields considerably more in winter and lets snow slide off, which in a flat arrangement leads to total failure. Second: cold noticeably reduces usable battery capacity. The two together mean that sizing on an annual average regularly comes out too tight. This assessment comes from practical application and does not replace a sizing calculation.
Mounting height beats antenna gain
In the 868 MHz band transmit power is capped by law, and nothing on the gateway changes it. What determines range is a clear line of sight. Every obstacle in the first Fresnel zone costs more than a stronger antenna can win back. And for antenna gain the counter-intuitive rule applies: more gain concentrates more flatly — good for flat terrain, bad for a tall mast above a valley, because the sensors below then fall out of the lobe.
Technical data
The general product data — protection rating, housing, processor, certifications, manufacturer part number and origin — is in the detail table further down this page.
| LoRaWAN | |
|---|---|
| Channels | 8, Semtech SX1303 concentrator |
| Operating modes | built-in network server, Basic Station, packet forwarder |
| Buffering | received frames are stored if the network server fails |
| LoRa antenna | external, not included — one per device |
| Connectivity | |
| Mobile | 4G LTE, antenna inside the housing |
| WiFi and GPS | antennas housed inside the enclosure |
| Ethernet | with PoE per 802.3af |
| Operation | |
| Power supply | 12 V DC, PoE (802.3af) or 12 V solar |
| Off-grid operation | connection to the manufacturer’s battery solution provided for |
| Protection rating | IP67 |
| Software | WisGateOS 2, remote management via WisDM |
| Processor | MT7628 |
Matching accessories
- LoRa antenna — mandatory: for sites in settlements or above varied ground the 3 dBi fibreglass antenna, for flat open terrain the 5 dBi version or the 8 dBi antenna.
- Surge protection — with every outdoor antenna: the RAK N-type surge arrester in the antenna line, and an RJ45 surge arrester in the network line.
- Mounting and cable: the L-type mounting kit for mast and wall, and for a remote antenna the 3 m antenna feeder line.
- The cheaper outdoor alternative: if IP65 is enough and the antennas may sit outside, the WisGate Edge Prime RAK7240CV2.
Installation and commissioning
Two steps decide the service life of an outdoor installation: the sealing of the antenna connection and the earthing. The connector belongs wrapped in self-amalgamating tape — water ingress in the plug is the most common reason range declines insidiously over months without anyone finding a fault. The earthing runs from the mast and the surge arrester to the equipotential bonding by the shortest route.
Check the radio link and the mobile reception while you are still up there. A second visit to a mast costs more than the whole commissioning.
Help with sizing
The datasheet and instructions are under the Documents tab at the top of this page. Planning an off-grid site and unsure about the panel, the battery or the antenna choice? Tell us where the gateway should stand and what it has to cover — the antenna question is gladly settled in conversation. And if it turns into a project — sizing the solar supply, radio planning or commissioning — we will gladly put together a quote.

Reviews