The Dragino D20S-LS is the D20 with the probe that is allowed into the ground: the same DS18B20, but in a TPE-sheathed cable that Dragino explicitly intends for burial in soil and in road surfaces. Two metres of cable take the probe to the depth where the question is decided — root zone, frost line, carriageway surface — while the IP66 enclosure stays up on the post and transmits. This is the solar-powered version: a panel charges a rechargeable 3000 mAh Li-ion cell, and the battery change disappears as long as enough light arrives.
- −55 … 125 °Cprobe range
- ±0.5 °Ctypical, max. ±2.0 °C
- 2 m TPEburiable probe cable
- IP66enclosure, probe IP65
- 3000 mAhLi-ion, solar charged
What defines the D20S-LS
- The probe is built to be buried: Dragino explicitly describes the S version as “designed for use in soil or road” and names TPE for the cable. That is the difference from the D20 — there the cable material is left open; here it is named, and TPE is the sheath that neither hardens nor turns brittle in the ground.
- A measuring range that covers most applications: −55 to +125 °C is not a marketing figure but the DS18B20’s range. For soil temperature that is far more than needed — and precisely why the same article stays usable when the next measuring point is on a heating return.
- Two metres of cable take the probe down: the device stays up where it has coverage and remains reachable; the probe lies at twenty centimetres, at half a metre, or under the surface. On a compact sensor both would be in the same place — unthinkable for a soil measurement.
- A digital bus, not analogue technology: the DS18B20 delivers a digital value. There is no characteristic curve to store, no line loss to compensate and no calibration at commissioning — unlike PT100s or thermocouples.
- An alarm flag in every message: a dedicated bit shows whether the value has left a set threshold. Thresholds are set by downlink, and so is the minimum time between two alarm messages — a sensor sitting at the frost line therefore does not flood the network.
- Recording when the network drops: if coverage fails, the device writes timestamped readings to its own memory and sends them on once the network is back. At measuring points out in a field, where coverage fluctuates, that is no side issue.
- Device status on its own port: model, firmware version, frequency band and battery arrive on FPort 5, separate from the readings on FPort 2. For a fleet that means the inventory can be queried without searching the measurement database.
- No battery change planned in: the solar panel charges a rechargeable 3000 mAh Li-ion cell. With sufficient light the replacement cycle disappears — at hard-to-reach measuring points the larger item over the service life. The cell is a buffer, not the main store: it carries the device overnight and through spells of bad weather.
- Configuration over the air: reporting interval and thresholds are set by downlink. The device can also be configured on site over Bluetooth 5.1 and its firmware updated wirelessly — the probe stays exactly where it lies.
- Not tied to a platform: LoRaWAN 1.0.3, Class A, OTAA. Runs on TTN, ChirpStack and the Swisscom LPN with the same device profile and the same decoder.
- The same electronics, four probe variants: anyone measuring above ground takes the D20 with its stainless probe; two measuring points on one device, the D22; three, the D23. Decoder and integration stay the same.
Where the D20S-LS is used
- Soil temperature in arable farming: germination temperature, timing of cultivation, spring warming. The probe sits at sowing depth, the device at the field edge.
- Frost warning in orchards and vineyards: soil temperature leads air temperature and is therefore an earlier indication than the air sensor alone.
- Road and path maintenance: surface temperature for black-ice warning and gritting plans — Dragino names the road surface explicitly as a place for this probe.
- Sports turf and golf greens: root zone temperature drives fertilisation, irrigation and playability.
- Greenhouse and raised bed: substrate temperature rather than air temperature — the quantity that actually governs root growth.
- Compost and silage: the probe sits in the heap, the device on a post. Self-heating caught early is the difference between turning the pile and a fire.
- Ground collectors and infiltration systems: temperature at the laying horizon, over years and without excavation.
- Large rollouts: one article, one decoder, one spare — and through the D20S-LS, D20S-NB and D20S-CB variants the same measuring technology with a different form of power or radio.
That covers the purchase decision. What follows is the depth needed for installation, integration and operation.
What “buriable” demands in practice
The manufacturer’s statement is brief: TPE sheath, two metres, for soil and road surfaces. That is half the answer. TPE really is the right sheath for this purpose — it stays flexible in the cold, absorbs almost no water and withstands UV and hydrolysis considerably better than soft PVC. What the statement does not contain is everything beyond the sheath.
Consequence for installation: three things decide whether a buried measuring point lasts for years. First, strain relief at the enclosure — the cable should not carry the load; a loop and a fixing to the mast should. Second, protection against the next spade: most failures come not from ageing but from the next excavation, which is why the position belongs marked and the cable, where possible, run inside a conduit. Third, a depth that matches the question — sowing depth is five to ten centimetres, the frost line sits around eighty depending on the region, and both with the same probe is not possible.
Assessment from field practice, not a manufacturer statement: with soil temperature the sensor’s own error is rarely the problem; the spread between two measuring points in the same field regularly exceeds the DS18B20’s half a degree. Anyone wanting to judge an area gains more from two simple measuring points in different places than from one more accurate one. And the laying depth belongs on record — a soil temperature without a stated depth is not a usable figure.
Payload and integration
The readings arrive on FPort 2 in eleven bytes of fixed order: two bytes of battery voltage in millivolts, two bytes of temperature from the connected probe as a signed value with a factor of ten, two unused bytes, one byte with the alarm flag, the operating mode and the state of input PA8, then two times two bytes for the probes this model does not have — they read 0x7FFF. D20, D20S, D22 and D23 share exactly this field layout; the decoder is the same for all of them.
Device status — model (0x19), firmware, frequency band, sub-band, battery — runs separately on FPort 5, and the replayed stored values on FPort 3. The latter each carry a four-byte Unix timestamp.
For the integration that means three things. First: the decoder has to evaluate the port, otherwise status messages land in the time series as implausible readings. Second: 0x7FFF is not a reading but “no probe” — anyone not catching it gets 3276.7 °C into the database. Third, and unlike the humidity sensors from the same brand: the live message on FPort 2 carries no timestamp. The measurement time here is the time of receipt; only the replayed stored values bring their own time.
Solar operation — what carries the balance and what tips it
A LoRaWAN uplink costs little energy: the radio is awake for fractions of a second and then sleeps on at a few microamps. That makes the solar balance here considerably more relaxed than on a cellular device — the daily demand is low enough that even an overcast winter day usually still covers it. The rechargeable 3000 mAh Li-ion cell is not meant as the main store but as a buffer overnight and through spells of bad weather.
Consequence for planning: what decides is not the cell capacity but where the panel sits. Facing south and unshaded all day, the balance carries; in the shade of a hedge, behind a roof edge or down a shaft it does not — and that shows in December, not in June.
Assessment from field practice, not a manufacturer statement: for the solar version Dragino gives neither a battery life nor a minimum irradiation. With two independent variables — location and reporting interval — that is consistent, but it does not help with planning. What is usable is the cell voltage carried in every message: anyone recording it through the first winter knows afterwards whether the site carries, instead of guessing.
Data at a glance
| Sensing element | 1 × Dallas DS18B20, IP65, 2 m cable with TPE sheath, for burial in soil or road surface |
| Temperature | −55 … +125 °C · ±0.5 °C typical, up to ±2.0 °C maximum · resolution 0.1 °C |
| Operating temperature | −40 … 85 °C (device) |
| Radio | LoRaWAN 1.0.3, Class A, OTAA · EU868 · up to +22 dBm · sensitivity down to −139 dBm |
| Payload | FPort 2 readings (11 bytes) · FPort 3 stored values with timestamp · FPort 5 device status |
| Configuration | LoRaWAN downlink · Bluetooth 5.1 on site · firmware update over the air |
| Power | solar panel with rechargeable 3000 mAh Li-ion cell · no battery-life figure from the manufacturer |
| Enclosure | IP66 · 200 × 120 × 55 mm · 372 g |
| Versions | D20S-LB LoRaWAN battery · D20S-LS LoRaWAN solar · D20S-NB NB-IoT · D20S-NS NB-IoT solar · D20S-CB LTE-M and NB-IoT · D20S-CS LTE-M and NB-IoT solar |
What the manufacturer does not state: a maximum laying depth, any statement on rodent resistance and a dimensioned drawing of the probe are all missing; the diameter and length of the sensing head appear neither on the product page nor in the manual. Whether the probe may sit permanently in groundwater is also unanswered — IP65 is specified for jets of water, not for permanent submersion. We are asking the manufacturer and will add it here.