Dragino S31-LS LoRaWAN temperature and humidity sensor, solar, 3 m probe, IP66 (868 MHz)

SKU:3JNJ
MPN:S31-LS
Brand:Dragino
Categories:
Sensoren:
Sensoren Thumbnail Sensoren Thumbnail
Availability CH:
not in stock0
From external stock:
Lead timein approx. 20 days
The lead time applies from 10 units. For smaller quantities please ask us. (?)

CHF72.23 excl. VAT

plus shipping

The solar version of the S31: the same Sensirion SHT31 in a condensation-protected sleeve on a 3 m cable, the same IP66 enclosure, ±0.2 °C and ±2 %RH — but with a solar panel and a rechargeable 3000 mAh cell instead of a lithium primary battery. For outdoor measuring points that nobody should have to touch for years. Without sufficient light the battery version S31-LB is the right choice.

! To operate this device you need a LoRaWAN network. You can build one yourself with a LoRaWAN gateway, use the LORIOT or TTN network, or rely on the Switzerland-wide Swisscom LoRaWAN. All of these networks are available from us.
 Add to comparison

The Dragino S31-LS is the solar-powered version of the S31: the same Sensirion transducer in a waterproof sleeve on a three-metre cable, the same IP66 enclosure, the same payload — but with a solar panel and a rechargeable cell instead of a lithium primary battery. It is therefore meant for measuring points nobody should have to touch for years: façade, field, mast, greenhouse roof. At ±0.2 °C and ±2 %RH it is considerably tighter than the usual room sensors. Where no light reaches, the battery version S31-LB is the right choice — not this one.

  • ±0.2 °Caccuracy, 0 … 90 °C
  • ±2 %RHhumidity, full range
  • 3 mprobe cable
  • IP66enclosure
  • 3000 mAhLi-ion, solar charged

What defines the S31-LS

  • Measurement is separated from radio: probe and transmitter are three metres apart. The measuring point can therefore be chosen by physics and the transmitter position by radio coverage — two requirements that regularly contradict each other on a compact device.
  • A Sensirion SHT31, not an in-house part: the transducer fitted has a public datasheet and behaviour documented over years. ±0.2 °C and ±2 %RH are not marketing but the component’s specification — and they sit a class above what simple room sensors deliver.
  • The probe is protected against condensation: the transducer sits in a waterproof sleeve that passes humidity but not water. This is precisely where open probes fail in cold stores and greenhouses: after the first condensation cycle they read permanently wrong.
  • The timestamp comes from the device: every message carries a Unix time from the sensor, not the network server’s receive time. If delivery is delayed the series therefore stays chronologically correct — the precondition for it to serve as evidence.
  • Alarm flag in every message: a dedicated bit shows whether the value has left a configured threshold. The back end does not have to test thresholds itself, and an alarm is not lost if processing falls behind.
  • Device status on its own port: model, firmware version, frequency band and battery arrive on FPort 5, separate from the readings on FPort 2. For a fleet that means inventory can be queried without searching the measurement database.
  • No battery change planned in: the solar panel charges a rechargeable 3000 mAh Li-ion cell. With sufficient light the replacement cycle disappears entirely — and across distributed outdoor measuring points that replacement costs more over the service life than the device itself.
  • Configuration over the air: reporting interval and thresholds are set by downlink. A device on a hall ceiling stays where it is.
  • Not tied to a platform: LoRaWAN 1.0.3, Class A, OTAA. Runs on TTN, ChirpStack and Swisscom LPN with the same device profile and the same decoder.
  • Power is the only difference: measuring and radio sections are identical to the battery-powered S31-LB, right down to the payload. A mixed fleet of solar and battery devices therefore needs only one decoder and one device profile.

Where the S31-LS is used

  • Cold stores, cold warehouses, ripening rooms: device outside, probe inside, cable through the door seal. The radio path does not run through the metal door — the reason cold-store monitoring otherwise has gaps.
  • Warehouses with humidity limits: paper, timber, electronics, animal feed. ±2 %RH is accurate enough to prove a limit rather than merely assert it.
  • Greenhouses and indoor growing: the probe hangs in the crop, the device on the post. Condensation-protected, so still able to measure after misting.
  • Plant rooms and halls: measurement under the ceiling or in the riser, transmitter at hand height. Maintenance without a ladder.
  • Drying and process monitoring: temperature and humidity at the point that governs the process, not at the point that happens to be accessible.
  • Outdoor climate on buildings: IP66 on the enclosure and a protected probe allow façade mounting; the operating range runs from −40 to 85 °C.
  • Evidence towards third parties: thanks to the device’s own timestamp the series stays unbroken and chronological even if delivery falls behind.
  • Large rollouts: one part number for indoor and outdoor measuring points, one decoder, one spare — and through the S31-LS variant the solar version as well, with no new integration.
No light, no solar operation. That is the one condition this device imposes, and it is regularly underestimated: a panel in permanent shade, behind dirty glass or indoors does not recharge enough, and you end up with a flat cell at a measuring point nobody is watching any more. For indoor spaces, chambers and cold stores the battery version S31-LB is therefore the right choice. The probe is the device — and it is fixed. The cable is three metres long and cannot be extended. For plain room-air measurement it is oversized. If probe and device end up in the same place anyway, the Dragino LHT52 does the same for a fraction of the price. Anyone who needs the transducer inside the enclosure should take the S31B. The ingress rating applies to the enclosure. The manufacturer states IP66 for the enclosure and describes the sleeve as waterproof and condensation-protected, but gives it no rating of its own. And there is no battery-life figure for the solar version. Dragino quotes the five years for the battery variant; how long the Li-ion cell lasts without light appears in no source. That belongs in the planning as a reserve, not as a known number.

That covers the purchase decision. What follows is the depth needed for radio planning, integration and operation.

Why three metres of cable are more than an accessory

On a compact device the transducer is where the antenna is. That sounds harmless but in practice decides whether a measurement is usable or not. Three examples, all with the same core: in a cold store the transmitter has to go outside because the metal door kills the radio path — the measurement has to stay inside. In a hall you need to measure where the warm air stands, so under the ceiling, while maintenance has to happen at hand height. In a greenhouse the probe belongs in the crop, but the transmitter belongs where it is not in the way of every operation.

Consequence for planning: the three metres are not a convenience but the degree of freedom that decouples the two requirements. They are also the limit — anyone needing more will not get further with this device, and an extension is no small matter on a digital SHT31 bus, because signal integrity depends on cable length.

Assessment from field practice, not a manufacturer statement: the probe sleeve is why this device stays usable for years in damp surroundings, and at the same time the reason for a sluggishness one needs to know about. A protected probe follows a humidity step more slowly than an open one — immaterial for room climate and storage, but not for controlling a fast drying process. Anyone wanting to capture steps on a scale of minutes should check that on the actual setup rather than infer it from the datasheet.

What solar operation means for planning

A solar-powered sensor trades a known effort for an unknown: the battery change disappears, but availability now depends on light. For Switzerland that means in practice that the critical time is not summer but the weeks around the winter solstice — short days, a shallow angle of incidence, high fog. A panel that delivers more than enough from April to October can fall below the charging balance in December, and you only notice when the measurement series breaks off.

Consequence for mounting: the panel belongs facing south and as steep as possible, so that snow slides off and the shallow winter incidence still strikes it. Leaves, bird droppings and dust cost more than one assumes; a clean in autumn is the cheapest measure against a failure in January. And the reporting interval is the strongest lever: going from ten to thirty minutes in winter cuts consumption markedly without giving up the measuring task.

Assessment from field practice, not a manufacturer statement: Dragino gives no battery life for the solar version, and that is consistent — without site and interval it would not be a dependable figure. For planning it is unsatisfying nonetheless. The cross-check via the battery variant helps: the same electronics lasts up to five years there on 8500 mAh. The solar cell has only 3000 mAh but has to bridge the dark period, not the whole service life. To be safe, plan the device with a light reserve and watch the cell voltage that comes with every message — it is the early warning, long before the series breaks off.

Payload and integration

Readings arrive on FPort 2 in fixed order: two bytes of battery voltage in millivolts, four bytes of Unix timestamp, one byte holding the alarm flag, the mode and the state of input PA8, then two bytes of temperature as a signed value with a factor of ten and two bytes of humidity with a factor of ten. Device status — model, firmware, frequency band, sub-band, battery — travels separately on FPort 5.

For the integration this means two things. First, the decoder must evaluate the port, otherwise status messages end up as implausible readings in the time series — an error that only shows when somebody analyses the data. Second, the transmitted timestamp should be used as the measurement time rather than the receive time. With LoRaWAN, minutes can pass between measurement and delivery; for a series serving as evidence that is the difference between right and nearly right.

Data at a glance

TransducerSensirion SHT31 in a waterproof, condensation-protected sleeve, 3 m cable
Temperaturesensor −40 … +80 °C · ±0.2 °C across 0 … 90 °C · resolution 0.1 °C
Humidity0 … 99.9 %RH · ±2 %RH across the full range · resolution 0.01 %RH
Operating temperature−40 … 85 °C
RadioLoRaWAN 1.0.3, Class A, OTAA · EU868
PayloadFPort 2 readings · FPort 5 device status
Powersolar panel with rechargeable 3000 mAh Li-ion cell · no battery-life figure from the manufacturer
EnclosureIP66 · 200 × 120 × 55 mm · 370 g
VersionsS31-LS solar · S31-LB with 8500 mAh Li-SOCl₂ · S31B with the transducer inside the enclosure

On the range figures: the manufacturer gives −40 to +80 °C for the sensor and an operating range of −40 to 85 °C for the device. The accuracy figure of ±0.2 °C refers to 0 to 90 °C and therefore extends beyond the sensor range — that is the SHT31 component’s specification, not the finished device’s. Outside 0 to 80 °C the tolerance is wider; by how much, Dragino does not say. For cold-store temperatures below 0 °C one should therefore not count on two tenths of a degree, but compare the setup once against a reference instrument.

+ Show more

Dokumente

Reviews

There are no reviews yet.

Be the first to review “Dragino S31-LS LoRaWAN temperature and humidity sensor, solar, 3 m probe, IP66 (868 MHz)”

Details

General
Brand
Dragino
Manufacturer part number
S31-LS
Colour
black
Interface
LoRa 868MHz
Version des LoRa (Long Range) Low-Power-Wireless-Chipsatzes, der auf verschiedenen Frequenzen arbeitet. Typischerweise für IoT-Anwendungen mit geringem Stromverbrauch und großer Reichweite verwendet.
Connectivity
Connectivity
LoRaWAN
Long Range Wide Area Network, ein drahtloses Protokoll für Low-Power-Geräte in weiträumigen Netzwerken, ideal für das IoT.
LoRaWAN specification
1.0.3
Device class
A
Klasse A-Geräte ermöglichen bidirektionale Kommunikation zwischen dem Gerät und dem Netzwerk. Nach jeder Uplink-Übertragung des Geräts sind zwei kurze Downlink-Empfangsfenster geöffnet. Diese Geräte haben die niedrigste Energieeffizienz und sind für Anwendungen geeignet, die keine festgelegten Empfangszeitpunkte erfordern. Beispielsweise könnte ein IoT-Sensor, der sporadisch Temperaturdaten an eine Cloud sendet, ein Klasse A-Gerät sein.
External antenna
yes
Frequencies
EU868
LoRaWAN-Frequenzband für Europa (868 MHz). Verwendet in Ländern wie Deutschland, Frankreich, Großbritannien und den meisten anderen europäischen Ländern.
Power supply
Power supply
Batterie
,
Solarstrom
Batteries included
Ja
Number of batteries
1
Battery type
Li-Ion
Replaceable battery
no
Mechanics/design
Product weight (g)
370
Width (mm)
120
Length (mm)
200
Height (mm)
55
IP code / rating
IP66
Staubdicht. Schutz gegen starkes Strahlwasser und bei Überflutung. Ein IoT-Sicherheitskamera im Freien könnte diesen Schutz haben.
Temperature range
-40 °C bis 85 °C
Humidity range
0 bis 100% RH
Commercial information
Country of origin
China
Other properties
Sensors
humidity
,
air temperature
Place of use
indoor and outdoor
Network server
ChirpStack
,
Swisscom LPN
,
TTN