The Dragino S31-LS is the solar-powered version of the S31: the same Sensirion transducer in a waterproof sleeve on a three-metre cable, the same IP66 enclosure, the same payload — but with a solar panel and a rechargeable cell instead of a lithium primary battery. It is therefore meant for measuring points nobody should have to touch for years: façade, field, mast, greenhouse roof. At ±0.2 °C and ±2 %RH it is considerably tighter than the usual room sensors. Where no light reaches, the battery version S31-LB is the right choice — not this one.
- ±0.2 °Caccuracy, 0 … 90 °C
- ±2 %RHhumidity, full range
- 3 mprobe cable
- IP66enclosure
- 3000 mAhLi-ion, solar charged
What defines the S31-LS
- Measurement is separated from radio: probe and transmitter are three metres apart. The measuring point can therefore be chosen by physics and the transmitter position by radio coverage — two requirements that regularly contradict each other on a compact device.
- A Sensirion SHT31, not an in-house part: the transducer fitted has a public datasheet and behaviour documented over years. ±0.2 °C and ±2 %RH are not marketing but the component’s specification — and they sit a class above what simple room sensors deliver.
- The probe is protected against condensation: the transducer sits in a waterproof sleeve that passes humidity but not water. This is precisely where open probes fail in cold stores and greenhouses: after the first condensation cycle they read permanently wrong.
- The timestamp comes from the device: every message carries a Unix time from the sensor, not the network server’s receive time. If delivery is delayed the series therefore stays chronologically correct — the precondition for it to serve as evidence.
- Alarm flag in every message: a dedicated bit shows whether the value has left a configured threshold. The back end does not have to test thresholds itself, and an alarm is not lost if processing falls behind.
- Device status on its own port: model, firmware version, frequency band and battery arrive on FPort 5, separate from the readings on FPort 2. For a fleet that means inventory can be queried without searching the measurement database.
- No battery change planned in: the solar panel charges a rechargeable 3000 mAh Li-ion cell. With sufficient light the replacement cycle disappears entirely — and across distributed outdoor measuring points that replacement costs more over the service life than the device itself.
- Configuration over the air: reporting interval and thresholds are set by downlink. A device on a hall ceiling stays where it is.
- Not tied to a platform: LoRaWAN 1.0.3, Class A, OTAA. Runs on TTN, ChirpStack and Swisscom LPN with the same device profile and the same decoder.
- Power is the only difference: measuring and radio sections are identical to the battery-powered S31-LB, right down to the payload. A mixed fleet of solar and battery devices therefore needs only one decoder and one device profile.
Where the S31-LS is used
- Cold stores, cold warehouses, ripening rooms: device outside, probe inside, cable through the door seal. The radio path does not run through the metal door — the reason cold-store monitoring otherwise has gaps.
- Warehouses with humidity limits: paper, timber, electronics, animal feed. ±2 %RH is accurate enough to prove a limit rather than merely assert it.
- Greenhouses and indoor growing: the probe hangs in the crop, the device on the post. Condensation-protected, so still able to measure after misting.
- Plant rooms and halls: measurement under the ceiling or in the riser, transmitter at hand height. Maintenance without a ladder.
- Drying and process monitoring: temperature and humidity at the point that governs the process, not at the point that happens to be accessible.
- Outdoor climate on buildings: IP66 on the enclosure and a protected probe allow façade mounting; the operating range runs from −40 to 85 °C.
- Evidence towards third parties: thanks to the device’s own timestamp the series stays unbroken and chronological even if delivery falls behind.
- Large rollouts: one part number for indoor and outdoor measuring points, one decoder, one spare — and through the S31-LS variant the solar version as well, with no new integration.
That covers the purchase decision. What follows is the depth needed for radio planning, integration and operation.
Why three metres of cable are more than an accessory
On a compact device the transducer is where the antenna is. That sounds harmless but in practice decides whether a measurement is usable or not. Three examples, all with the same core: in a cold store the transmitter has to go outside because the metal door kills the radio path — the measurement has to stay inside. In a hall you need to measure where the warm air stands, so under the ceiling, while maintenance has to happen at hand height. In a greenhouse the probe belongs in the crop, but the transmitter belongs where it is not in the way of every operation.
Consequence for planning: the three metres are not a convenience but the degree of freedom that decouples the two requirements. They are also the limit — anyone needing more will not get further with this device, and an extension is no small matter on a digital SHT31 bus, because signal integrity depends on cable length.
Assessment from field practice, not a manufacturer statement: the probe sleeve is why this device stays usable for years in damp surroundings, and at the same time the reason for a sluggishness one needs to know about. A protected probe follows a humidity step more slowly than an open one — immaterial for room climate and storage, but not for controlling a fast drying process. Anyone wanting to capture steps on a scale of minutes should check that on the actual setup rather than infer it from the datasheet.
What solar operation means for planning
A solar-powered sensor trades a known effort for an unknown: the battery change disappears, but availability now depends on light. For Switzerland that means in practice that the critical time is not summer but the weeks around the winter solstice — short days, a shallow angle of incidence, high fog. A panel that delivers more than enough from April to October can fall below the charging balance in December, and you only notice when the measurement series breaks off.
Consequence for mounting: the panel belongs facing south and as steep as possible, so that snow slides off and the shallow winter incidence still strikes it. Leaves, bird droppings and dust cost more than one assumes; a clean in autumn is the cheapest measure against a failure in January. And the reporting interval is the strongest lever: going from ten to thirty minutes in winter cuts consumption markedly without giving up the measuring task.
Assessment from field practice, not a manufacturer statement: Dragino gives no battery life for the solar version, and that is consistent — without site and interval it would not be a dependable figure. For planning it is unsatisfying nonetheless. The cross-check via the battery variant helps: the same electronics lasts up to five years there on 8500 mAh. The solar cell has only 3000 mAh but has to bridge the dark period, not the whole service life. To be safe, plan the device with a light reserve and watch the cell voltage that comes with every message — it is the early warning, long before the series breaks off.
Payload and integration
Readings arrive on FPort 2 in fixed order: two bytes of battery voltage in millivolts, four bytes of Unix timestamp, one byte holding the alarm flag, the mode and the state of input PA8, then two bytes of temperature as a signed value with a factor of ten and two bytes of humidity with a factor of ten. Device status — model, firmware, frequency band, sub-band, battery — travels separately on FPort 5.
For the integration this means two things. First, the decoder must evaluate the port, otherwise status messages end up as implausible readings in the time series — an error that only shows when somebody analyses the data. Second, the transmitted timestamp should be used as the measurement time rather than the receive time. With LoRaWAN, minutes can pass between measurement and delivery; for a series serving as evidence that is the difference between right and nearly right.
Data at a glance
| Transducer | Sensirion SHT31 in a waterproof, condensation-protected sleeve, 3 m cable |
| Temperature | sensor −40 … +80 °C · ±0.2 °C across 0 … 90 °C · resolution 0.1 °C |
| Humidity | 0 … 99.9 %RH · ±2 %RH across the full range · resolution 0.01 %RH |
| Operating temperature | −40 … 85 °C |
| Radio | LoRaWAN 1.0.3, Class A, OTAA · EU868 |
| Payload | FPort 2 readings · FPort 5 device status |
| Power | solar panel with rechargeable 3000 mAh Li-ion cell · no battery-life figure from the manufacturer |
| Enclosure | IP66 · 200 × 120 × 55 mm · 370 g |
| Versions | S31-LS solar · S31-LB with 8500 mAh Li-SOCl₂ · S31B with the transducer inside the enclosure |
On the range figures: the manufacturer gives −40 to +80 °C for the sensor and an operating range of −40 to 85 °C for the device. The accuracy figure of ±0.2 °C refers to 0 to 90 °C and therefore extends beyond the sensor range — that is the SHT31 component’s specification, not the finished device’s. Outside 0 to 80 °C the tolerance is wider; by how much, Dragino does not say. For cold-store temperatures below 0 °C one should therefore not count on two tenths of a degree, but compare the setup once against a reference instrument.

Reviews