The MClimate Wireless Thermostat is the control unit on the wall — the place where someone in the room can say how warm they want it. It measures temperature, humidity, light level and motion, shows it all on an E-Ink display and reports it over LoRaWAN. What makes it unusual: it needs neither a cable nor battery changes, because an organic solar module powers it from the light in the room. Important to understand — it does not regulate anything itself. It supplies readings and the user’s wish; another device has to move the valve.
- solarfrom room light, no battery
- 2.9" E-Inkreadable without backlight
- 4 readingstemperature, humidity, light, motion
- 3 buttonstarget set on the device
What sets the Wireless Thermostat apart
- It lives off the light in the room: an organic solar module powers the device. No battery changes, no cable, no maintenance cycle — across a hundred rooms that is exactly the item that decides the operating costs.
- E-Ink rather than a screen: the display only uses energy when it changes and then stays put. That is what makes it possible on a solar-powered device — and why it stays readable in any light, without glowing.
- The user gets a voice: three buttons with which the target can be adjusted. That sounds trivial but it is the difference between a system that regulates over people’s heads and one that is accepted. Anyone who cannot intervene throws the window open.
- Four readings instead of one: temperature and humidity for the climate, light level and motion for occupancy. Only together do they explain why a room is too warm — sun, people or heating.
- It reports on event and on schedule: an uplink goes out both on every change and regularly. A target change is therefore in the system immediately, without having to transmit constantly.
- Open to any system: the data runs over LoRaWAN and integrates into any compatible platform, including building management. No tie to a manufacturer’s cloud.
- Flat and unobtrusive: 115 × 105 × 23 mm on the wall. In offices and classrooms it is not perceived as equipment, and that is decisive for acceptance.
Where it is used
- Offices and meeting rooms: record the room climate and give users a way to adjust, without pulling a cable.
- Schools and public buildings: many rooms, no wiring, no maintenance effort from batteries.
- Individual room control in existing buildings: together with radio-controlled radiator heads, a complete control system arises without building work.
- Occupancy-based control: motion and light readings show whether a room is in use — the basis for not heating empty rooms.
- Connection to building management: as a room sensor and control unit for an existing system.
- Hotels and accommodation: guests can adjust, the operator sees the occupancy.
That settles the selection. What follows is the depth for planning and operation.
Measuring, operating, actuating — three jobs, two devices
Individual room control falls into three parts: something measures, somebody sets a wish, and something moves the valve. This device handles the first two. The third sits on the radiator. In between stands the logic — and that does not run in the thermostat but on your network server or in the building management system.
At first that is more effort than one device combining everything. There is a reason for it: the control point belongs where people are — at eye level on the wall — and the actuator belongs at the valve, often behind a curtain or under a windowsill. A thermostat head on the radiator measures the temperature where it says least about the room. The separation is therefore not a detour but the better control.
What the solar module has to deliver
Organic solar cells are designed for indoor light and still deliver energy at a few hundred lux — that is the difference from ordinary silicon cells, which give up almost nothing there. The device’s consumption is correspondingly low: E-Ink only draws current when switching, and transmission happens only when needed.
For planning that means: the mounting position decides. An inner wall opposite the window is good, a recess beside the cupboard is bad. Rooms that stay unused and dark for weeks are the borderline case — there it is worth checking after a few weeks of operation whether the device holds up, before fifty more are ordered.
Technical data
The general product data — dimensions, manufacturer part number and origin — is in the detail table further down this page.
| Measured quantities | temperature, humidity, light level, motion (passive infrared) |
| Display | E-Ink, 2.9 inch |
| Operation | 3 buttons, target adjustable directly on the device |
| Power supply | organic solar module, operation from room light |
| Batteries | none included and not required in normal operation |
| Radio | LoRaWAN, integrable into any compatible platform and building management system |
| Reporting behaviour | uplink on every event and additionally periodically |
| Actuating function | none — the device measures and takes input, it does not actuate a valve |
The matching counterpart
- The actuator on the radiator: the MClimate Vicki replaces the thermostat head and carries out what is set here. Only together do the two make individual room control.
- The network to go with it: without LoRaWAN there is no data path — for indoor use the RAK7268CV2 WisGate Edge Lite 2+ is our best-selling gateway.
Help with sizing
Planning individual room control and unsure how control unit, actuator and logic work together, or whether the light in your rooms is enough for solar operation? Tell us how many rooms are involved — these questions are gladly settled in conversation. And if it turns into a project — sizing, pre-configuration or connection to your building management system — we will gladly put together a quote.

Reviews
There are no reviews yet.